57 results (0,22015 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Zeta ZT-500EX Triple UVIR Flame Detector ATEX Approved

Zeta ZT-20EX UVIR Flame Detector ATEX Approved

3 Litre Commander Wet Chemical Extinguisher - WCEX3

6 Litre Commander Wet Chemical Extinguisher - WCEX6

Commander F-Class Wet Chemical 6 Litre Refill Pack RP26

Apollo Intelligent Triple IR Flame Detector 55000-020APO

Apollo Intelligent Flameproof IR3 Flame Detector 55000-021APO

Commander SE10 9kg Monex Dry Powder

Elmdene ACCESS-UL-PSU2 UL294 12V 4A PSU With 4 Way Fused Output Module In D Box

Elmdene ACCESS-UL-PSU2 UL294 12V 4A PSU With 4 Way Fused Output Module In D Box

Elmdene ACCESS-UL-PSU2 UL294 12V 4A PSU With 4 Way Fused Output Module In D BoxElmdenes UL294-certified power solutions have been designed for compatibility with the most common access control door controllers. They offer installation flexibility and are a time-saving solution for system designers.These enclosures are engineered to accommodate multiple door controllers providing power integration within access control systems. This enables robust power management to ensure seamless operation and optimised performance of your access control systems.By choosing Elmdenes compliant power solutions you can rest assured that your access control systems will operate smoothly and efficiently. These power solutions are the perfect fit for system designers who value flexibility and reliability in their power supply solutions.This high efficiency cost effective UL294-listed power supplycharger is designed for use in Access Control systems enclosed in two spacious cabinet choices each fitted with locks and tamper switch.Regulated 13.8Vdc output with battery stand-by supplying rated current to 4 independently PTC Fused Outputs resettable fuses individually configured for continuous or switched output current via a fire relay switch with flexible trigger options capable of operating with any external control signal. PSU Universal mains input. Two dry volt free contacts are provided to signal loss of mains and battery output faults.Key FeaturesSingle and Multi-door solutions12V standby battery chargingMulti-fused outputs are providedMains fail reportingBattery Monitoring and Deep Discharge Protection ACCESS-UL-PSU1 and ACCESS-UL-PSU2Independent ancillary relay for applications such as a Fire door release relayIntegration with door controllers including Mercury Security ProWatch HoneywellD Enclosure 505 x 407 x 80

GBP 280.66
1

Elmdene ACCESS-UL-PSU1 UL294 12V 4A PSU With 4 Way Fused Output Module In G Box

Elmdene ACCESS-UL-PSU1 UL294 12V 4A PSU With 4 Way Fused Output Module In G Box

Elmdene ACCESS-UL-PSU1 UL294 12V 4A PSU With 4 Way Fused Output Module In G BoxElmdenes UL294-certified power solutions have been designed for compatibility with the most common access control door controllers. They offer installation flexibility and are a time-saving solution for system designers.These enclosures are engineered to accommodate multiple door controllers providing power integration within access control systems. This enables robust power management to ensure seamless operation and optimised performance of your access control systems.By choosing Elmdenes compliant power solutions you can rest assured that your access control systems will operate smoothly and efficiently. These power solutions are the perfect fit for system designers who value flexibility and reliability in their power supply solutions.This high efficiency cost effective UL294-listed power supplycharger is designed for use in Access Control systems enclosed in two spacious cabinet choices each fitted with locks and tamper switch.Regulated 13.8Vdc output with battery stand-by supplying rated current to 4 independently PTC Fused Outputs resettable fuses individually configured for continuous or switched output current via a fire relay switch with flexible trigger options capable of operating with any external control signal. PSU Universal mains input. Two dry volt free contacts are provided to signal loss of mains and battery output faults.Key FeaturesSingle and Multi-door solutions12V standby battery chargingMulti-fused outputs are providedMains fail reportingBattery Monitoring and Deep Discharge Protection ACCESS-UL-PSU1 and ACCESS-UL-PSU2Independent ancillary relay for applications such as a Fire door release relayIntegration with door controllers including Mercury Security ProWatch HoneywellG Enclosure 440 x 250 x 115

GBP 241.67
1

Apollo Flameproof Intelligent IR2 Flame Detector 55000-295APO

Fireclass 540.001.038FC XB8 Intrinsically Safe Xenon Beacon

Apollo Intelligent Dual IR Flame Detector 55000-280APO

Morley FS20X-211-24-6 Stainless Steel IR2 UV Zone 1 Flame Detector

Morley FS20X-211-24-6 Stainless Steel IR2 UV Zone 1 Flame Detector

Morley FS20X-211-24-6 Stainless Steel IR2 UV Zone 1 Flame DetectorBased on the foundation of the highly successful and reliable SS4 detector the FS20X detector represents a quantum leap in integrating Infrared and Ultraviolet sensing technologies. The FS20X is a Multi-Spectrum and UVDual IRVIS fire and flame detector with a proven UV solar-blind sensor. The FS20X exhibits faster false-alarm free response to fires over a wider temperature range and with a much longer detection range compared to conventional UVIR detectors. Conventional and older technology UVIR detectors using narrow band 4.3 micron IR sensors will not respond to smokyfires or if the detector lens is contaminated with oil and other substances since both UV and 4.3 micron signals are attenuated obscured or absorbed by thick smoke or detector lens contaminations. All UV sensors will be attenuated to some degree. Also these old technology UVIR detectors will not alarm to any fire if they are installed behind ordinary window glass.The FS20 detector using advanced patented algorithms for signal processing and fire and flame analysis is designed to alarm to all types of fires in all industrial environmental conditions. If the detectors UV signal is degraded due to heavy smoke or a contaminated lens the FS20Xs patented WideBand IR Near Band IR and Visible sensors will still alarm to fire albeit at a reduced sensitivity and slower response time.Key FeaturesPatented WideBand IR Infrared combined with UltravioletDetection range greater than 60 m 200 feet to 0.1 m2 1 sq. ft. heptane firePatented Electronic Frequency AnalysisVisible sensor for optimum false alarm rejectionSelectable detection sensitivitiesSolar blind 90 cone-of-visionDual microprocessors for reliable performanceReal-time clock for accurate time dating of eventsFirePic Up to 6 pre-fire event data storageEvent log Up to 200 events with date and time stampBuilt-in RS-485 ModBus communicationBuilt-in non-isolated 4-20 mA analog output sink or sourceAlarm Fault and Fire Verification relaysAutomatic Optical Path and Electronic self-testPatented Electronics Module for component protection with plug-in terminations for easy field installationTwo 25 mm conduit entries or two NPTLow power consumptionHigh RFI and EMI immunityFM hazardous area approvedEx d ATEX approvedCU-TR approvedINMETRO approvedMeets SIL 2 requirementsCertified to EN54-102002 optionFM 3260 performanceApplicationsRefineries and oil production facilitiesOff-Shore platformsTurbineCompressor enclosuresAcetylene processing and storageOil and Gas pipelines and pumping stationsLNGLPG loading and unloading facilitiesNatural Gas and CNG plantsEthanol Methanol and IPA production and storageCrude oil and gasoline storage and tank farmsAircraft hangarsHydrogen plants and storagePaint and solvent storageChemical production storage and loading facilitiesPower plantsSilane gas storage

GBP 3434.89
1

Vesda Xtralis PIP-012 250ml Solvent Cement

Vesda Xtralis PIP-012 250ml Solvent Cement

Vesda Xtralis 250ml Solvent CementSolvent cement welding is a simple and quick means of constructing high integrity leak free joints. Care must be used to ensure that the correct solvent cement is used and that joining instructions are followed properly.This specially formulated solvent cement is used with ABS pipe and fittings to join the surfaces together. The solvent cement melts the two surfaces to form a chemical weld when applied correctly between the fittings.Key FeaturesSolvent cement for ABSContains 250mlProduct InformationSeparate COSHH statement availableIntended usage Jointing of pipeworkPacking 0.25 litre cans Acorn FireConstituents ABS resin dispersed in MethylEthyl KetoneShelf life 12 months minimumPhysical Product DataBoiling Point 80CVapour pressure 100mm Mercury at 25CVapour density 1.18 at 20C 2.4 at boilingpointSpecific gravity 0.86Solubility in Water MiscibleAppearance Grey opaque fluid Strong odourBefore Applying Solvent CementBe aware at all times of good safety practicesSolvent cements are flammableEliminate all ignition sourcesDo not smoke during use and do not expose to other sources of heat or flame in working or storage areasAvoid breathing vaporsUse only with adequate ventilationExplosion proof mechanical ventilation or local exhaust is recommended to maintain vapor concentrations below recommended exposure limitsIn confined areas a NIOSH approved organic vapor cartridge respirator with full-face piece is recommendedCement should be stored in the shade at temperatures between 40F and 110F Acorn FireContainers should be kept tightly closed when not in use and covered as much as possible during useAvoid contact with eyes.Splash proof chemical goggles are recommendedAvoid frequent contact with skinWearing PVA coated gloves and an impervious apron are recommendedSolvent cements have a limited shelf life and must be used prior to the expiration dateRefer to printed warnings on cement can and Material Safety Datasheets for additional informationWARNINGSolvent cement and cleanersARE HAZARDOUSFLAMMABLE MATERIALS. Do not joint nearnaked names and avoid smoking in the working area.Do not use cements or cleaners in confined spaces.Concentrated vapours may cause dizziness.Please Note The PIP-012 is equivalent to the REDCEM.

GBP 14.63
1

STI WRP2-G-01-CL Outdoor Reset Point - Green Series 01 Custom Label

Commander FX-WCH-003 3ltr Wet Chemical Fire Extinguisher CommanderEDGE

Apollo Exd Conventional Triple IR Flame Detector 55000-062APO

Apollo I.S. Conventional Triple IR Flame Detector 55000-063APO

Vesda Xtralis PIP-009 25mm Pipe Clip Pack of 20

Nittan RP-RS2-01NTN Conventional Indoor RESET Call Point IP24 cw Back Box and Wall Plate

Carrier 116-BG-21 Facade Standalone IR2 Flame Detector

Vesda Xtralis White Pipe Clip - Pack of 20 PIP-009-W

Carrier 116-BG-21F Facade IR2 Flame Detector Kit

Notifier Honeywell ABT-EKB-20M Microphone Keyboard Extension