CST GEN2-INT Per InputOutput Message Module

CST GEN2-INT Per InputOutput Message Module

CSTGEN2-INTPer InputOutput Message ModuleTheGEN2-INT is an InputOutput Message Module for the GEN2 Software.GEN2 is a software solution that controls and monitors an entire messaging and alarm monitoring operation. Its the hub of all communication sending and receiving messages or alerts from all departments equipment and staff members.Only the most efficient hotels run on Gen2 a software solution that controls and monitors an entire messaging and alarm monitoring operation. Gen2 is high performing multi-lingual user-friendly and Windows-based with the ability to facilitate an unlimited amount of client users. It is the hub of all communication sending and receiving messages or alerts from all departments equipment and staff members.Pre-set or formulate messages using the QWERTY keyboardand communicate critical events and data to any end point. Gen2 can send recurring messages and prompts such as maintenance reminders as well as one-time instant messages.Gen2 can route alerts to individuals or entire groups via different connections. As events escalate so can your recipient list. Whether its a status update or a life-safety alert you can be confident the right people will receive the information.Hot KeysUnlimited programmable hot keys for pre-defined and pre-set messages enabling swift alerts to pagers radios DECT phones email addresses and mobile users.Quick KeysImportant messages or alerts can be pre-set here easy to see and making communication to defined groups quick and simple.Multi-LingualGen2 supports English German French Spanish Dutch and standard Arabic.Quick SendUse the Qwerty keyboard to write and send all messages to any end user.Incoming MessagesView all incoming messages including time date and message in one single place.UsersGroupsContactsA list of all users contactable via Gen2 are listed here.Cloud StorageUsers can log in to Gen2 via Android and iOS operating devices.

GBP 339.07
1

Kentec Boxed Sigma XT Ancillary PCB cw 0.75 A PSU Surface K03750M2

Hochiki LA-WLDM LEAKalarm Addressable Interface Module 2 Detection Zones

Klaxon TCC-0012 MTL 7728 Shunt Diode Safety Barrier

C-Tec CA737 EACIE 4 Way Flat Interface No PSU In Cabinet Extendable To 8 Way

EMS Firecell Fusion FCX-532-001 Radio Loop Module

Cooper CFVCSHP VoCall Type A Surface Mounted Outstation

Cooper CFVCHP VoCall Type A Flush Mounted Outstation

Carrier 9-30855-18 EN 54-4 approved 24 V 5 A 0.7 A Intelligent Power Supply

Carrier 9-30855-18 EN 54-4 approved 24 V 5 A 0.7 A Intelligent Power Supply

Carrier 9-30855-18 EN 54-4 approved 24 V 5 A 0.7 A Intelligent Power SupplyThe 9-30855-18 is a fully featured 24 V EN54-4 approved power supply ideal for use in fire system applications. The output current is split between the load and charging the batteries. It features intelligent battery charging monitoring and signaling while providing deep discharge protection to prevent premature battery failure when operating from standby for extended periods.On the front of the unit diagnostic LEDs indicate the status of the power supply with various flash patterns to ensure accurate diagnostics when the unit is in fault.The range is available in different size of output currents with support for various sizes of batteries.Installer friendlyThe power supply is supplied in a self-contained wall mounting box that can also house 18 Ah batteries not included.Selection of the battery size is easy with the use of a jumper. Similarly a jumper is used to select between dual-path or two individual outputs. With this feature mission critical applications can be powered ensuring redundancy in the supply of 24 V to the load.On the front of the unit 6 LEDs indicated the status of the power supply. To aid with the interpretation of the meaning of the LEDs a legend is used on the front of the unit. Additionally there is also a diagnostics LED that with different flash patterns indicated even more detailed information.A potential-free contact is used to signal faults due to output failure battery fault charger fault or internal fault. A second potential-free contact signals the loss of mains power.EN 54-4 approved 24 V 5 A 0.7 A intelligent power supplyApproved to EN54-4 VdS certifiedSelf contained box houses 18 Ah batteriesDeep battery discharge protectionDiagnostics leds on front of housing2 x relay outputsDetailsApproved to EN54-4 VdS certifiedSelf contained box houses 18 Ah batteriesDeep battery discharge protectionDiagnostics leds on front of housing2 x relay outputsDual load connection terminalsWide input voltage range

GBP 357.18
1

Fike 520-0010 CIE-A-200 Repeater Panel

Morley EVCS-HSP Surface Type A Push Door Outstation

Morley EVCS-HFP Flush Type A Push Door Outstation

Zeta TS-OSR Type A Telephone Outstation - Red Handset

Zeta TS-OSWP Type A Telephone Outstation - Weatherproof IP66