1.562 results (0,54259 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Wagner AD-10-5130 Detector Module f. ProSens amp SILENT

Wagner AD-10-5130 Detector Module f. ProSens amp SILENT

Wagner AD-10-5130 Detector Module f. ProSens SILENTThe Wagner AD-10-5130 DM-TP-50-L is a detector module for use with the Titanus ProSens smoke aspiration detection system.The universal TITANUSPRO.SENSis WAGNERs best-selling air sampling smoke detector. Depending on the situation the one or two detector modules each with a one-stage alarm can be set to sensitivity levels as high as 0.015 obs.m on their primary alarms. The highly modular air sampling smoke detection system offers solutions for both simple and highly specialised areas of application.WAGNERs TITANUSPRO.SENSair sampling smoke detector is designed to monitor large areas of up to 5760 m. Thanks to a combination of innovative High Power Light Source HPLS technology and patented LOGIC.SENSfire pattern recognition the TITANUSPROSENSprovides maximum sensitivity and security against false alarms even in difficult environmental conditions.Key FeaturesThe TITANUSPROSENSmonitors rooms and equipment using two detector modules in a dual-detector dependency configuration.Additional alarm indicators can be connected as desired.The number of air sampling points can be freely adapted to individual circumstances up to 1 x 100 or 2 x 72 points.A range of DIN EN 54-20 certified accessories provides even greater modularity thus making the TITANUSPROSENSair sampling smoke detector an even more cost-effective option.It is available in Standard SILENT 23 dB A and up for noise-critical areas and Cold Storage for temperatures as low as -40 C versionsa specific fire protection solution for any area of application.TITANUSPipeXpressProject planning and configuration is fast and secure.The plug-and-play system makes commissioning quick and easy.

GBP 432.46
1

Hochiki LA-WLDM LEAKalarm Addressable Interface Module 2 Detection Zones

Aritech ABT-LA60 Fire Line Array Loudspeaker - Power 60W 100V

Aritech ABT-LA60 Fire Line Array Loudspeaker - Power 60W 100V

Aritech ABT-LA60 Fire Line Array Loudspeaker - Power 60W 100VABT-LA fire-alarm loudspeakers mean a new quality among the facilities of the kind. ABT-LA30 and ABT-LA60 units are line-array loudspeaker columns which means they ensure considerably farther reach than conventional units at simultaneous maintenance of high uniformity of sound level in the area of broadcasting. Being line-array acoustic sources ABT-LA columns feature a unique high directionality in vertical plane so that the sound they generate will rather go exactly towards the controlled audiospace instead of unwanted areas such as e.g. ceiling or floor. ABT-LA columns are mostly designed for the rooms with high reverberation time as well as for other places where the quality of speech is reduced due to unfavourable conditions.The ABT-LA design allows easy mechanical and electrical integration of the two columns into a single consistent unit which becomes a loudspeaker with higher power output and farther reach. It makes a better use of the benefits offered by the line-array source. Variable geometry of the column allows generating two sound beams to be randomly sent at various angles to the two different areas. Sound transfer band of the ABT-LA columns has been designed to achieve the highest possible fidelity of speech signal reproduction and to ensure unchallenged parameters of the quality of speech all as required by the standards applicable to the Voice Evacuation Systems.Solid aluminium enclosure steel assembly jigs and IP 65 guarantee long-term failure-free operations under any conditions both in outdoor and indoor environments. The columns are entirely dustproof and resistant to the impact of direct water jet.Key FeaturesLine Array Loudspeakers Columns

GBP 415.54
1

Aritech ABT-LA30 Fire Line Array Loudspeaker - Power 30W 100V

Aritech ABT-LA30 Fire Line Array Loudspeaker - Power 30W 100V

Aritech ABT-LA30 Fire Line Array Loudspeaker - Power 30W 100VABT-LA fire-alarm loudspeakers mean a new quality among the facilities of the kind. ABT-LA30 and ABT-LA60 units are line-array loudspeaker columns which means they ensure considerably farther reach than conventional units at simultaneous maintenance of high uniformity of sound level in the area of broadcasting. Being line-array acoustic sources ABT-LA columns feature a unique high directionality in vertical plane so that the sound they generate will rather go exactly towards the controlled audiospace instead of unwanted areas such as e.g. ceiling or floor. ABT-LA columns are mostly designed for the rooms with high reverberation time as well as for other places where the quality of speech is reduced due to unfavourable conditions.The ABT-LA design allows easy mechanical and electrical integration of the two columns into a single consistent unit which becomes a loudspeaker with higher power output and farther reach. It makes a better use of the benefits offered by the line-array source. Variable geometry of the column allows generating two sound beams to be randomly sent at various angles to the two different areas. Sound transfer band of the ABT-LA columns has been designed to achieve the highest possible fidelity of speech signal reproduction and to ensure unchallenged parameters of the quality of speech all as required by the standards applicable to the Voice Evacuation Systems.Solid aluminium enclosure steel assembly jigs and IP 65 guarantee long-term failure-free operations under any conditions both in outdoor and indoor environments. The columns are entirely dustproof and resistant to the impact of direct water jet.Key FeaturesLine Array Loudspeakers Columns

GBP 293.42
1

Advanced MxPro5 MXP-503F Network Card - Standard Fitted

Advanced MxPro5 MXP-503F Network Card - Standard Fitted

Advanced MxPro5 MXP-503F Network Card - Standard FittedThe Ad-NeT network system allows all MxPro 5 series control panels remote terminals and network peripherals to be connected together using standard fire resistant two-core cable. It provides both the benefits of distributed intelligence and reduced installation costs whilst catering for the smallest two-panel network through to the largest 200 panel wide area networked system.The network operates as a true peer-to peer system allowing information from any input or output device to be passed over the network and displayed on any MxPro 5 control panel or remote terminal as required.Simply adding and connecting a network card allows any MxPro 5 control panel or remote terminal to be networked. All other nodes on the Ad-NeT system will be instantly aware of a panel as soon as it is given a valid network node address allowing additional panels to be added at any time. All panels incorporate a network analyser providing valuable diagnostic and status information and also have the facility to prevent the transmission of fires or faults during commissioning.For more complex systems the Windows based PC-NeT Mx configuration software allows sector based programming for Mute Silence Resound and Reset control keys as well as investigation delays group disablement and test instructions. All panels within the same sector will share common controls and each panel or remote terminal can also be programmed to show specific network information on a zonal basis. For cause and effect any input device can be programmed to operate any output device on any panel.Key FeaturesLarge Ad-NeT 200 Panel NetworkUp to 1.5Km between Control PanelsWindows based PC setupNetwork Systems share up to 1000 zonesNetwork Analysis from Control Panel

GBP 234.06
1

Advanced Mxp-003 Standard Network Card MXPro 4

Advanced MXP-503 Standard Network Card MxPro5

Advanced MXP-503 Standard Network Card MxPro5

Advanced MXP-503 Standard Network Card MxPro5The Ad-NeT network system allows all MxPro5 series control panels remote terminals and network peripherals to be connected together using standard fire resistant two-core cable. It provides both the benefits of distributed intelligence and reduced installation costs whilst catering for the smallest two-panel network through to the largest 200 panel wide area networked system.The network operates as a true peer-to peer system allowing information from any input or output device to be passed over the network and displayed on any MxPro5 control panel or remote terminal as required.Simply adding and connecting a network card allows any MxPro5 control panel or remote terminal to be networked. All other nodes on the Ad-NeT system will be instantly aware of a panel as soon as it is given a valid network node address allowing additional panels to be added at any time. All panels incorporate a network analyser providing valuable diagnostic and status information and also have the facility to prevent the transmission of fires or faults during commissioning.For more complex systems the Windows based PC-NeT Mx configuration software allows sector-based programming for Mute Silence Resound and Reset control keys as well as investigation delays group disablement and test instructions. All panels within the same sector will share common controls and each panel or remote terminal can also be programmed to show specific network information on a zonal basis. For cause and effect any input device can be programmed to operate any output device on any panel.Key FeaturesLarge Ad-NeT 200 Panel NetworkUp to 1.5Km between Control PanelsWindows based PC setupNetwork Systems share up to 1000 zonesNetwork Analysis from Control PanelStandard NetworkThe maximum total cable length is 1.5km. The maximum number of network nodes is 32 50 with signal bufferFault Tolerant NetworkThe maximum cable length is 1.5km between each node and the maximum total loop length is 20km. Each network card has in-built diagnostics and is fully monitored for both short and open circuit faults between nodes. The network is capable of withstanding a single fault between nodes without loss of communications to any single panel. The maximum number of network nodes is 200.

GBP 234.06
1