Carrier 9-30855-65 EN 54-4 approved 24 V 3 A 2.6 A Intelligent Power Supply A

Kidde Airsense 9-30855-38 EN 54-4 Approved 24 V 4 A 1.5 A Intelligent Power Supply

Kidde Airsense 9-30855-38 EN 54-4 Approved 24 V 4 A 1.5 A Intelligent Power Supply

Kidde Airsense 9-30855-38 EN 54-4 Approved 24 V 4 A 1.5 A Intelligent Power SupplyThe 9-30852-38 is a fully featured 24V EN54-4 approved power supply ideal for use in fire system applications. The output current is split between the load and charging the batteries. It features intelligent battery charging monitoring and signalling while providing deep discharge protection to prevent premature battery failure when operating from standby for extended periods.The power supply is supplied in a self-contained wall mounting box that can also house 38 Ah batteries not included. Selection of the battery size is easy with the use of a jumper. Similarly a jumper is used to select between dual-path or two individual outputs.With this feature mission critical applications can be powered ensuring redundancy in the supply of 24 V to the load.On the front of the unit 6 LEDs indicated the status of the power supply. To aid with the interpretation of the meaning of the LEDs a legend is used on the front of the unit. Additionally there is also a diagnostics LED that with different flash patterns indicated even more detailed information.A potential-free contact is used to signal faults due to output failure battery fault charger fault or internal fault. A second potential-free contact signals the loss of mains power.Key FeaturesProviding deep discharge protectionIntelligent battery charging monitoring and signallingDiagnostics LEDs on front of housingExternal housing for 38Ah batteriesDual load connection terminals2x Relay outputs

GBP 499.93
1

Fike 540-0010 CIE-A-400 Repeater Panel

Fike 540-0010 CIE-A-400 Repeater Panel

Fike 540-0010 CIE-A-400 Repeater PanelThe CIE-A-400 Addressable Fire Alarm Control Panel is a two-loop panel capable of each loop supporting up to 200 devices with a maximum loop length of 2KM. The panel also provides two configurable Monitored Input Circuits 2 configurable Monitored Output Circuits 2 configurable Relays 1 Fault Relay and also a Peripheral Bus Circuit to add up to 8 Repeater Panels.The system may be configured utilising 3 alarm stages with full Zone to Zone Cause and Effect across all 32 panel zones with provision to include Alarm Confirmation and Delay Timers. An additional 32 output zones are also provided for more complex Cause and Effect programming.The CIE-A-400 control panel is compatible with Fikes addressable range of devices and utilises soft addressing principles eliminating the need for the installer to physically address each device whilst also eradicating time spent on faults caused by duplicate addressing. The operating parameters of the devices are configured either from the panel or via the OSP programming software and are then stored within the flash memory of the device itself. This enhanced digital protocol means less information is needed to be sent between the detector and the host control panel resulting in faster more reliable communication.Key FeaturesSimply install and plug into Peripheral busRepeater control panel for the Fike CIE-A-400 2 loop addressable fire panelUp to 8 repeater panels can be connected on the same systemAllows control of the system from remote locations to the main fire panelRequires mains supply and 12v 12Ah back up batteriesSurface mount as standard flush mountable with additional cradle part number 23-0239

GBP 563.36
1

Cooper Menvier TA16-RS Type A Outstation - Red - Surface Mount

Cooper Menvier TA16-SS Type A Outstation - Stainless Steel - Surface Mount

Kidde 1-23911-K116 FireBeta A-XT Extinguishing Control Panel

Kidde 1-23911-K116 FireBeta A-XT Extinguishing Control Panel

Kidde 1-23911-K116 FireBeta A-XT Extinguishing Control PanelThe Kidde 1-23911-K116 FireBeta A-XT Extinguishing Control Panel is a ULFM listed extinguishing control panel designed and manufactured to the highest standards in a quality controlled environment. With UL and FM approvals it offers outstanding value and performance for small to medium sized fixed firefighting installations. FireBeta A-XT is supplied in a red enclosure.The 3 initiation circuits allow extinguishant release to be configured to activate from any combination of detection zone inputs. This allows among others any 2 zones from the combination of 3 to activate release making it ideal for applications protecting ceiling room and floor voids.The extensive configuration options of the FireBeta A-XT allow the functionality of the system to be extensively modified. A large LED display on the panel fascia enables easy configuration and control. It additionally displays the time remaining until extinguishing agent release for added user safety.Key FeaturesUL864 and FM listedThree initiation circuits as standardAny single zone or any combinations of zones can be configured to releaseConfigurable first stage NAC delaysConfigurable detection delaysZero time delay upon manual release optionCompatible with I.S. barriersNon-latching zone input option to receive signals from other systems such as aspirating equipmentConfigurable releasing delays up to 60 seconds in 5 second stepsConfigurable releasing duration up to 5 minutes in 5 second stepsCountdown timer shows time remaining to releaseSupports up to seven four wire status indicatorsBuilt in extract fan control

GBP 536.48
1

Ziton ZP2-AFR-99 ZP2-A Addressable Fire Repeater Panel

Ziton ZP2-AFR-99 ZP2-A Addressable Fire Repeater Panel

Ziton ZP2-AFR-99 ZP2-A Addressable Fire Repeater PanelThe Ziton ZP2-AFR-99 addressable fire panel repeater comes with a 2010-2-NB network board already fitted. Except for having no addressable loops and corresponding programmable outputs the setup is similar as a normal fire panel. It and has its own power supply 2 conventional relay outputs and 2 supervised outputs working in pair and dedicated to common fire and fault conditions as well as 2 user configurable inputs for monitoring and control are available.OptionsThe repeaters use a node on the network similar like a normal panel with a maximum of 64 nodes 256 loops network of fire panels and fire panel repeaters including conventional fire panels and fire panel repeaters up to a maximum of 64 conventional zones. Last but not least in case separate zone indications are required a 20 or 40 zone firefault LED indicator board can be mounted in the panel or repeater with ample space for text.Network compatible with existing panels repeaters existing and new and conventional panels.ZP2-A OverviewThe new ZP2-A series life safety control systems bring the speed and functionality of high-end intelligent processing to small to mid-sized addressable applications. Based on ZP2 series learned experience and with complete backwards compatibility the new ZP2-A features an attractive contemporary design that fits with any decor. With improved robustness manufactured in metal special plastics and easy electronics removal it allows painting in any colour. The main controls are easily located using an improved and robust jog dial.With high power loop addressable detection a full line of easily configured option cards and modules as well as USB and Ethernet connectivity these quick-to configure systems offer versatility that benefits building owners and life safety system installers alike.Key Features Local or global repeater with or without global control functionality Up to 40 LED zone indicators for Fire and Fault with ample text space Auto configuration setup wizards and default regional setup modes Ethernet port with TCPIP for remote diagnostics maintenance and programming EN54 compliant graphical LCD with icons and up to 256 zones Improved Jog Dial with 4 soft buttons for simple and intuitive user control Pleasing design with robust painted steel door Easy removable door and chassis for quick and clean installation All pluggable connectors 3 USB ports with memory stick support and RS232 for printer support 3 operator level menu structure 20 usernames and passwords Email notification for events directly from the panel 4 user accounts History log memory for 9999 events Backwards compatible supporting site retrofitupgrades expansions replacement Comes standard fitted with network board

GBP 717.90
1

Kentec DNX-A-2R-K RS485 Dynamic Network Analyser

Kentec DNX-A-2R-K RS485 Dynamic Network Analyser

Kentec DNX-A-2R-K RS485 Dynamic Network AnalyserThe DNX-A-2R-K is an RS485 Dynamic Network Analyser for Ring Topology Networks. This product has been developed to facilitate dynamic network management through the provision of an independent communication layer.The equipment is designed to improve the Quality of Service QoS of critical communication networks while operating under the performance criteria required by EN54-13 and BS5839 part 1.The ports connected to the communications ring are correctly terminated to match the network communications cable impedance to ensure optimum signal quality and amplitude.Signal quality is constantly monitored and the termination impedance is adjusted to compensate for changes in cable impedance due to climatic or physical cable parameter changes.Four InputOutput interfaces are provided for through an independent communications layer. This feature provides a basic redundant network protocol with the mapping configuration managed through the PC graphics IVIEW programming tool.An upgrade license DNX-R-2R-K-UG is available for this module which enables compatibility with IVIEW graphical software for network analysis support.Key FeaturesIndependent reporting with Class A communication redundancy with multiple fault tolerance2.5 kV galvanic isolation on all portsDual and single industrial equipment RS485 connection4 independent IO channels across the redundant network ring for independent protocol redundancyCan operate on Hosted Fibre Ethernet linksSimple LED system status indicationSignal quality and amplitude visual indicationWireless connectivity for remote monitoring using a Bluetooth or WiFi interfaceSupports the generation of system performance reports for Installation commissioningVisual interface provide by IVIEW the graphical user interface with monitoring diagnostics and reporting optionsEnables preventative maintenance management through system degradation monitoringConfiguration and commissioning parameters are stored allowing for system performance tracking over timeBaud rate selectable from 9600-115200 bitssecDIN rail mounting

GBP 1591.74
1

Morley EVCS-HSA-RS-D Digital Type A Outstation - Red Surface Mount

Baldwin Boxall CARE2 Type A Stainless Steel Fire Telephone with Lock Door C2FTSL

Ziton ZP2-AF1-S ZP2-A - 1 Loop Addressable Panel

Ziton ZP2-AF1-S ZP2-A - 1 Loop Addressable Panel

Ziton ZP2-AF1-S ZP2-A - 1 Loop Addressable PanelCertification EN54-2 EN54-4 EN54-2OverviewThe new ZP2-A series life safety control systems bring the speed and functionality of high-end intelligent processing to small to mid-sized addressable applications. Based on ZP2 series learned experience and with complete backwards compatibility the new ZP2-A features an attractive contemporary design that fits with any decor. With improved robustness manufactured in metal special plastics and easy electronics removal it allows painting in any colour. The main controls are easily located using an improved and robust jog dial.The PanelThe fire panels supplied in local language with user interface with 1 loop that supports up to 254 devices 127 addresses in 512 zones have standard 2 supervised sounderfire-routing outputs which can be used as freely programmable outputs as well. In addition 2 conventional relay outputs and 2 supervised outputs working in pair and dedicated to common fire and fault conditions as well as 2 user configurable inputs for monitoring and control are available.OptionsThe panel supports one network board to create a maximum of 64 nodes 256 loops network of fire panels and fire panel repeaters including conventional fire panels and fire repeater panels up to a maximum of 64 conventional zones. Last but not least in case seperate zone indications are required a 20 or a 40 zone firefault LED indicator board can be mounted in the panel or repeater with ample space for custom text. Compatible with existing loop devices and network compatible with existing panels repeaters existing and new and conventional panelsApprovals compliance CE CPD EN54-2 EN54-4 EN54-21 WEEE RoHS compliantDetails 1 High Power Loop with 800 mA per loop 512 zones and 300 output groups Up to 24 LED zone indicators for Fire and Fault with space for a 4 digit number Auto configuration setup wizards and default regional setup modes Ethernet port with TCPIP for remote diagnostics maintenance and programming EN54 compliant graphical LCD with icons and up to 256 zones Improved Jog Dial with 4 soft buttons for simple and intuitive user control Aesthetic pleasing design with robust painted steel door Easy removable door and chassis for quick and clean installation All pluggable connectors

GBP 564.11
1

Notifier IDR2-A Active Repeater Panel For ID50 ID60 amp ID2000

Lexicomm ViLX-OSC Surface Combined Type A Telephone and Type B Refuge Point

Lexicomm ViLX-OSC Surface Combined Type A Telephone and Type B Refuge Point

Lexicomm ViLX-OSC Surface Combined Type A Telephone and Type B Refuge PointThe ViLX-OSC is a combined Type A and Type B EVCS outstation compatible with the Lexicomm standalone and network systems.The outstation is supplied in a brushed stainless finish with a Type B refuge panel on the front with a high contrast red screen print with a rugged red telephone handset behind the push door.A stainless steel bezel is available to allow the outstation to be flushed into a wall reducing the need to stock flush and surface variants.Combined Outstations are designed to be used where the disabled refuge area is within the fire fighting lift lobby of a building.The outstation is supplied in a brushed stainless finish with a Type B refuge panel on the front with a high contrast red screen print with a fighting telephone accessed by pushing the door picking up the telephone disables the refuge call point.SuitabilityThe ViLX-OSC is a combined Type A and Type B outstation as defined in BS5839-92011 and can be used as a fire telephone or a disabled refuge call point. The Lexicomm outstations are designed for use by multi-disability users having high contrast signage in line with RNIB guidelines and an induction loop coil to BSEN60118-4 in the handset. ViLX-OSC outstations are mainly used when the disabled refuge area is located within the firefighting lift lobby as described in BS9999 and Building Regulations Approved Document B these locations should have a low background noise otherwise you may have to consider acoustic hoods.Mounting the OutstationThe outstation should be mounted at a height of 1250mm from to the centre line of the outstation to the floor to comply with the requirements of Building Regulations Document M Access for the Disabled. When flush mounting a cut out of 305mm by 155mm is recommended the bezel slides over the box and is fixed on the wall using a suitable sealant or mastic As the outstation is also to be used as a refuge point suitable space should be allowed so the system can be used by a parked wheelchair.Key FeaturesCompact DesignRuggedised HandsetHigh Volume RingerStatus LED20mm Cable Gland knock-outTelecoil for hearing impaired usersFull Duplex OperationFully Compliant to BS5839-92011Magnetic Push CatchStainless Steel as standardFlush bezel available

GBP 521.14
1

Cygnus SN.CIE30.A SmartNet Pro 96 Zone Control Panel

Cygnus SN.CIE20.A SmartNet Pro 64 Zone Control Panel

Kentec K1810-12 Sigma A-XT Extinguishant Control Panel 115V Red

Kentec K1810-12 Sigma A-XT Extinguishant Control Panel 115V Red

Kentec K1810-12 Sigma A-XT Extinguishant Control Panel 115V RedSigma A-XT releasing panel offers outstanding value and performance for all small to medium fixed fire-fighting installations.With three initiating circuits as standard release can be configured to activate from any combination of detection zone inputs to allow among other combinations any two from three types of activations for detection in ceiling void room and floor void applications.The extensive configuration options of the Sigma A-XT allow the functionality of the system to be extensively modified. The panel contains a large LED display to enable easy configuration and control which also displays the time remaining until release for added user safety.The countdown time is duplicated on up to seven remote status units to provide local indication of the system status.With all the electronics mounted on a single easily removable steel plate Sigma A-XT panels are both robust and easy to install. Sigma A-XT is supplied in an enclosure that matches the design and colour of the Elite RS range and is available in standard red or optional grey.The K16400M2 from the extensive range of Kentec products is a syncro IO expansion card enclosure with 5.25A power supply. flexibility to create customised IO panel.Key FeaturesUL864 and FM ListedThree initiation circuits as standardAny single zone or any combinations of zones can be configured to releaseConfigurable first stage NAC delaysConfigurable detection delaysZero time delay upon manual release optionSupports up to seven four wire status indicatorsBuilt in Extract Fan controlCompatible with I.S. barriersNon-latching zone input option to receive signals from other systems such as aspirating equipmentConfigurable releasing delays up to 60 seconds in 5 second stopsConfigurable releasing duration up to 5 minutes in 5 second stepsCountdown timer shows time remaining until release

GBP 628.31
1

Kentec K1810-13 Sigma A-XT Extinguishant Control Panel - 230V Red

Kentec K1810-13 Sigma A-XT Extinguishant Control Panel - 230V Red

Kentec K1810-13 Sigma A-XT Extinguishant Control Panel - 230V RedSigma A-XT releasing panel offers outstanding value and performance for all small to medium fixed fire-fighting installations.With three initiating circuits as standard release can be configured to activate from any combination of detection zone inputs to allow among other combinations any two from three types of activations for detection in ceiling void room and floor void applications.The extensive configuration options of the Sigma A-XT allow the functionality of the system to be extensively modified. The panel contains a large LED display to enable easy configuration and control which also displays the time remaining until release for added user safety.The countdown time is duplicated on up to seven remote status units to provide local indication of the system status.With all the electronics mounted on a single easily removable steel plate Sigma A-XT panels are both robust and easy to install. Sigma A-XT is supplied in an enclosure that matches the design and colour of the Elite RS range and is available in standard red or optional grey.The K16400M2 from the extensive range of Kentec products is a syncro IO expansion card enclosure with 5.25A power supply. flexibility to create customised IO panel.Key FeaturesUL864 and FM ListedThree initiation circuits as standardAny single zone or any combinations of zones can be configured to releaseConfigurable first stage NAC delaysConfigurable detection delaysZero time delay upon manual release optionSupports up to seven four wire status indicatorsBuilt in Extract Fan controlCompatible with I.S. barriersNon-latching zone input option to receive signals from other systems such as aspirating equipmentConfigurable releasing delays up to 60 seconds in 5 second stopsConfigurable releasing duration up to 5 minutes in 5 second stepsCountdown timer shows time remaining until release

GBP 628.31
1

Kentec K1810-43 Sigma A-XT Extinguishant Control Panel - 230V Grey

Kentec K1810-43 Sigma A-XT Extinguishant Control Panel - 230V Grey

Kentec K1810-43 Sigma A-XT Extinguishant Control Panel - 230V GreySigma A-XT releasing panel offers outstanding value and performance for all small to medium fixed fire-fighting installations.With three initiating circuits as standard release can be configured to activate from any combination of detection zone inputs to allow among other combinations any two from three types of activations for detection in ceiling void room and floor void applications.The extensive configuration options of the Sigma A-XT allow the functionality of the system to be extensively modified. The panel contains a large LED display to enable easy configuration and control which also displays the time remaining until release for added user safety.The countdown time is duplicated on up to seven remote status units to provide local indication of the system status.With all the electronics mounted on a single easily removable steel plate Sigma A-XT panels are both robust and easy to install. Sigma A-XT is supplied in an enclosure that matches the design and colour of the Elite RS range and is available in standard red or optional grey.The K16400M2 from the extensive range of Kentec products is a syncro IO expansion card enclosure with 5.25A power supply. flexibility to create customised IO panel.Key FeaturesUL864 and FM ListedThree initiation circuits as standardAny single zone or any combinations of zones can be configured to releaseConfigurable first stage NAC delaysConfigurable detection delaysZero time delay upon manual release optionSupports up to seven four wire status indicatorsBuilt in Extract Fan controlCompatible with I.S. barriersNon-latching zone input option to receive signals from other systems such as aspirating equipmentConfigurable releasing delays up to 60 seconds in 5 second stopsConfigurable releasing duration up to 5 minutes in 5 second stepsCountdown timer shows time remaining until release

GBP 628.31
1

Kentec K1810-44 Sigma A-XT Extinguishant Control Panel - 115V Grey

Kentec K1810-44 Sigma A-XT Extinguishant Control Panel - 115V Grey

Kentec K1810-44 Sigma A-XT Extinguishant Control Panel - 115V GreySigma A-XT releasing panel offers outstanding value and performance for all small to medium fixed fire-fighting installations.With three initiating circuits as standard release can be configured to activate from any combination of detection zone inputs to allow among other combinations any two from three types of activations for detection in ceiling void room and floor void applications.The extensive configuration options of the Sigma A-XT allow the functionality of the system to be extensively modified. The panel contains a large LED display to enable easy configuration and control which also displays the time remaining until release for added user safety.The countdown time is duplicated on up to seven remote status units to provide local indication of the system status.With all the electronics mounted on a single easily removable steel plate Sigma A-XT panels are both robust and easy to install. Sigma A-XT is supplied in an enclosure that matches the design and colour of the Elite RS range and is available in standard red or optional grey.The K16400M2 from the extensive range of Kentec products is a syncro IO expansion card enclosure with 5.25A power supply. flexibility to create customised IO panel.Key FeaturesUL864 and FM ListedThree initiation circuits as standardAny single zone or any combinations of zones can be configured to releaseConfigurable first stage NAC delaysConfigurable detection delaysZero time delay upon manual release optionSupports up to seven four wire status indicatorsBuilt in Extract Fan controlCompatible with I.S. barriersNon-latching zone input option to receive signals from other systems such as aspirating equipmentConfigurable releasing delays up to 60 seconds in 5 second stopsConfigurable releasing duration up to 5 minutes in 5 second stepsCountdown timer shows time remaining until release

GBP 628.31
1

Ziton ZP2-AF1 ZP2-A - 1 Loop Addressable Panel

Ziton ZP2-AF1 ZP2-A - 1 Loop Addressable Panel

Ziton ZP2-AF1 ZP2-A - 1 Loop Addressable PanelCertification EN54-2 EN54-4 EN54-2The new ZP2-A series life safety control systems bring the speed and functionality of high-end intelligent processing to small to mid-sized addressable applications. Based on ZP2 series learned experience and with complete backwards compatibility the new ZP2-A features an attractive contemporary design that fits with any decor. With improved robustness manufactured in metal special plastics and easy electronics removal it allows painting in any colour. The main controls are easily located using an improved and robust jog dial.The PanelThe fire panels supplied in local language with user interface with 1 loop that supports up to 254 devices 127 addresses in 512 zones have standard 2 supervised sounderfire-routing outputs which can be used as freely programmable outputs as well. In addition 2 conventional relay outputs and 2 supervised outputs working in pair and dedicated to common fire and fault conditions as well as 2 user configurable inputs for monitoring and control are available.OptionsThe panels supports one network board to create a maximum of 64 nodes 256 loops network of fire panels fire panel repeaters including conventional fire panels and fire panel repeaters up to a maximum of 64 conventional zones. Last but not least in case seperate zone indications are required a 20 or 40 zone firefault LED indicator board can be mounted in the panel or repeater with ample space for text. Compatible with existing loop devices and network compatible with existing panels repeaters existing and new and conventional panels.Approvals compliance CE CPD EN54-2 EN54-4 EN54-21 WEEE RoHS compliantDetails 1 High Power Loop with 800 mA per loop Up to 512 zones and 300 output groups Up to 40 LED Zone indicators for Fire and Fault with ample text space Auto configuration setup wizards and default regional setup modes Ethernet port with TCPIP for remote diagnostics maintenance and programming EN54 compliant graphical LCD with icons and up to 256 zones Improved Jog Dial with 4 soft buttons for simple and intuitive user control Aesthetic pleasing design with robust painted steel door Easy removable door and chassis for quick and clean installation All pluggable connectors Auxiliary 24 VDC supply output with reset support 3 USB ports with memory stick support and RS232 for printer support Communication via UltraSync cloud using EN 54-21 UC240 UltraSync communicator Integration in management software ATS8600 allowing integration with security systems and CMS 3 operator level menu structure 20 usernames and passwords Email notification for events directly from the panel 4 user accounts History log memory for 9999 events Backwards compatible supporting site retrofitupgrades expansions replacement Compatible with the Ziton loop powered soundersbeacons and base sounders and Ziton series detectors

GBP 564.11
1

Baldwin Boxall CARE2 Type A Green Steward Emergency Telephone with Lock Door C2ETGL

Morley EVCS-HSA-SS-D Digital Type A Outstation - Stainless Steel Surface Mount