TS3-6PACK-001 Replacement Testifire Smoke Capsules

TC3-6PACK-001 Replacement Testifire CO Capsules

Baldwin Boxall Ambient Noise Weatherproof Sensor BVRAMBIP

Baldwin Boxall Ambient Noise Weatherproof Sensor BVRAMBIP

Baldwin Boxall Ambient Noise Weatherproof Sensor BVRAMBIPWhen designing a voice alarm system for areas of variable levels of ambient noise which could cause problems with audibility noise sensors should be included. Correctly placed ambient noise sensors will ensure that all announcements are clearly heard.Key FeaturesTwo versions are available BVRAMB - standard version. BVRAMBIP - IP65 rated version.Monitors the ambient noise in a given area.Automatically adjusts the power of the amplifiers depending on noise level.When the area is at its quietest the level of the announcements or music will reduce.During busynoisy periods the volume level adjusts to suit.Used in conjunction with a BVRDCI CANBUS interface module which connects to the VIGIL EVAS routers.Uses a dynamic microphone capsule the output of which is amplified and converted to produce a variable current.This output is used by the BVRDCI module to produce a voltage that is proportional to the ambient noise.Band pass filtering ensures that the system only responds to ambient noise affecting the intelligibility of announcements.An on-board surveillance tone generator permanently monitors the microphone capsule. A system fault will be indicated should the microphone capsule or on-board amplifier fail.The BVRAMB includes an option to allow one of three response speeds to be selected SLOW - the system will only respond to an average change of ambient noise. MEDIUM - suitable for most installations. FAST - the system will react to short duration changes in ambient noise.Two units can be wired in parallel on the same input to monitor the ambient noise over a larger area.

GBP 530.71
1

Testifire 2001 Urban Smoke Heat amp CO Detector Test Kit 5 Metres

Testifire 1001 Urban Smoke amp Heat Detector Test Kit 5 Metres

Testifire 9201-001 Smoke Heat and CO Detector Test and Removal Kit - 9 Metres 30 ft

Testifire 9201-001 Smoke Heat and CO Detector Test and Removal Kit - 9 Metres 30 ft

Testifire 9201-001 Smoke Heat and CO Detector Test and Removal Kit - 9 Metres 30 ftNow Including High Capacity Battery BatonsTestifire 2000 Series is the worlds first multi-stimulus detector tester for smoke heat and CO fire detectors. Smoke heat and CO stimuli are created in a single test unit and delivered individually or - for the first time - simultaneously in whichever combination are required.Testifire does this without using pressurised cans of gas or other hazardous goods. Stimuli Smoke Heat and CO are generated at the time of test using safe and patented processes fuelled by replaceable capsules.The new SOLO770 Battery Baton is a higher capacity product 3000mAh. It allows greater efficiency both in the field and on site as it gives more tests per battery for the same charge time as before but provided by the new SOLO727 Battery Charger.The SOLO727 charger has also been improved and while it provides the same functionality as before it is now capable of enabling fast charging of the new higher capacity battery batons from both mains power and in-vehicle outlets.Features BenefitsTesting with one tool is faster and more productiveLess tools and equipment to carry aroundAllows testing and removal of detectors up to 9 metres 30 ft in heightCombined stimuli delivers quicker activation times for combination detectorsUnique Clearing Cycle provides rapid detector reset with no repeat alarmsTest times reduced by as much as 66 saving labourFully reverse compatible with the Solo range of poles battery batons and chargers.Ideal in any application Land Air and MarineA must have addition to any Professional Engineers Tool SuiteReduced carriage and shipping costs - no pressurised cans of gasReduced Test Stimuli Re-stocking and freight costs - no pressurised cans of gasTestifire 9201 - 001 Smoke Heat and CO Detector Testing and Removal Kit Includes1 x Testifire 2000-001 Head Unit inside the 2001-001 box it will also include 1 x TS3-001 Smoke Capsule 1 x TC3-001 CO Capsule 1 x Solo 770-001 Battery Baton option to buy second baton in the drop-down box and 1 x Solo 727-001 Multi Voltage Fast Charger1 x Solo 100-001 Fibreglass Telescopic Access Pole 4.5 metres 15 ft3 x Solo 101-001 Fibreglass Extension Pole 1.13 metres 4 ft1 x Solo 200-001 Universal Detector Removal Tool1 x Solo 610-001 Protective Carrying Storage Bag

GBP 4123.44
1

Testifire 6201-001 Smoke Heat and CO Detector Test and Removal Kit - 6 Metres 20 ft

Testifire 6201-001 Smoke Heat and CO Detector Test and Removal Kit - 6 Metres 20 ft

Testifire 6201-001 Smoke Heat and CO Detector Test and Removal Kit - 6 Metres 20 ftNow Including High Capacity Battery BatonsTestifire 2000 Series is the worlds first multi-stimulus detector tester for smoke heat and CO fire detectors. Smoke heat and CO stimuli are created in a single test unit and delivered individually or - for the first time - simultaneously in whichever combination are required.Testifire does this without using pressurised cans of gas or other hazardous goods. Stimuli Smoke Heat and CO are generated at the time of test using safe and patented processes fuelled by replaceable capsules.The new SOLO770 Battery Baton is a higher capacity product 3000mAh. It allows greater efficiency both in the field and on site as it gives more tests per battery for the same charge time as before but provided by the new SOLO727 Battery Charger.The SOLO727 charger has also been improved and while it provides the same functionality as before it is now capable of enabling fast charging of the new higher capacity battery batons from both mains power and in-vehicle outlets.Features BenefitsTesting with one tool is faster and more productiveLess tools and equipment to carry aroundAllows testing and removal of detectors up to 6 metres 20 ft in heightCombined stimuli delivers quicker activation times for combination detectorsUnique Clearing Cycle provides rapid detector reset with no repeat alarmsTest times reduced by as much as 66 saving labourFully reverse compatible with the Solo range of poles battery batons and chargers.Ideal in any application Land Air and MarineA must have addition to any Professional Engineers Tool SuiteReduced carriage and shipping costs - no pressurised cans of gasReduced Test Stimuli Re-stocking and freight costs - no pressurised cans of gasTestifire 6201 - 001 Smoke Heat and CO Detector Testing and Removal Kit Includes1 x Testifire 2000-001 Head Unit inside the 2001-001 box it will also include 1 x TS3-001 Smoke Capsule 1 x TC3-001 CO Capsule 1 x Solo 770-001 Battery Baton with option to buy a second in the drop down box above and 1 x Solo 727-001 Multi Voltage Fast Charger1 x Solo 100-001 Fibreglass Telescopic Access Pole 4.5 metres 15 ft1 x Solo 200-001 Universal Detector Removal Tool1 x Solo 610-001 Protective Carrying Storage Bag

GBP 3763.45
1

Testifire 1000-001 Smoke and Heat Detector Tester - Head Only

Baldwin Boxall Four Zone Emergency Fire Microphone BFM404

Baldwin Boxall Single Zone Emergency Fire Microphone BFM401

Baldwin Boxall Eight Zone Emergency Fire Microphone BFM408

Testifire 2000-001 Smoke Heat and CO Detector Tester - Head Only

Kidde Airsense EST-DFMS Fireman Microphone

Kidde Airsense EST-DFMS Fireman Microphone

Kidde Airsense EST-DFMS Fireman MicrophoneA EST ENT VES fireman microphone is a monitored external device working with Control Units in a redundant communication ring. It can thereby perform a superior function of a system control unit too.A fireman microphone can be used to activate alarm messages as well as general public announcements to choose individual zones and to broadcast live voice messages. It is equipped with programmable function keys which can be used to assign functions as required. Up to 5 EST-EKB-20M keyboard extensions with additional function keys can be attached to a fireman microphone.A CPU switch enables immediate and direct broadcasting of announcements to all zones without any involvement of the control system even during a failure of the central processor. The microphone is able to automatically detect a key failure and an audio path from the microphone capsule inclusive to the Control Unit. A fireman microphone is also equipped with an intercom function and is able to communicate with other microphones in the system.Key FeaturesMonitored microphone and connection of the microphone module to the systemA dedicated evacuation key 3 fully-programmable keys with a possibility of connecting up to five 20-key extensionsBuilt-in 2 contact inputs and 2 relay outputsPOE or external feeder-based power supplyBlack-box function recording all announcements played during an alarmBuilt-in SFP modules and CAT5e for simplicity of implementation of the loop topologyRS485 for communication with external systemsIntercom function between all fireman and zone microphones

GBP 1256.28
1

Baldwin Boxall 16 Zone Intelligent Paging Microphone BDM416

Baldwin Boxall 16 Zone Intelligent Paging Microphone BDM416

Baldwin Boxall 16 Zone Intelligent Paging Microphone BDM416BDM400 microphones for public address and voice alarm systems. The BDM400 range of intelligent paging microphones is designed to provide a wide variety of features to suit any installation. There are six microphones available in the range one-zone to 32-zone.Key FeaturesAvailable in six versions - from one-zone up to 32-zone.Communicate with the main control system via an RS485 link.A standard RJ45 CAT5 network cable is used to carry both audio and serial data.Microphones can be linked together via wall sockets - product code BMS8 and connected to a single input at the control rack.The BDM401 can also be operated as a parallel microphone. This option is selected internally by jumpers. Factory setting is for serial operation.Ergonomic design with all buttons and indicators mounted behind a stylish overlay that allows zone button labels to be inserted and protected.The dynamic cardoid microphone capsule can be set for either monitored or unmonitored use during configuration.Zone status indicators show if a zone is currently selected or in use.All call paging except BDM401.Speak now indicator to show the user when a pre-announcement chime has finished.Simple bar graph display shows the user the current speech volume ensuring a clear announcement is made.Data and DC indicators to show the unit is functioning correctly.Zonal fault indicators are included to show when a fault is evident on the system.Fault accept button.Option to fit flip-top switches to enable DVA digital voice announcement messages to be broadcast.

GBP 863.65
1

Baldwin Boxall 8 Zone Intelligent Paging Microphone BDM408

Baldwin Boxall 8 Zone Intelligent Paging Microphone BDM408

Baldwin Boxall 8 Zone Intelligent Paging Microphone BDM408BDM400 microphones for public address and voice alarm systems. The BDM400 range of intelligent paging microphones is designed to provide a wide variety of features to suit any installation. There are six microphones available in the range one-zone to 32-zone.Key FeaturesAvailable in six versions - from one-zone up to 32-zone.Communicate with the main control system via an RS485 link.A standard RJ45 CAT5 network cable is used to carry both audio and serial data.Microphones can be linked together via wall sockets - product code BMS8 and connected to a single input at the control rack.The BDM401 can also be operated as a parallel microphone. This option is selected internally by jumpers. Factory setting is for serial operation.Ergonomic design with all buttons and indicators mounted behind a stylish overlay that allows zone button labels to be inserted and protected.The dynamic cardoid microphone capsule can be set for either monitored or unmonitored use during configuration.Zone status indicators show if a zone is currently selected or in use.All call paging except BDM401.Speak now indicator to show the user when a pre-announcement chime has finished.Simple bar graph display shows the user the current speech volume ensuring a clear announcement is made.Data and DC indicators to show the unit is functioning correctly.Zonal fault indicators are included to show when a fault is evident on the system.Fault accept button.Option to fit flip-top switches to enable DVA digital voice announcement messages to be broadcast.

GBP 635.04
1

Baldwin Boxall 24 Zone Intelligent Paging Microphone BDM424

Baldwin Boxall 24 Zone Intelligent Paging Microphone BDM424

Baldwin Boxall 24 Zone Intelligent Paging Microphone BDM424BDM400 microphones for public address and voice alarm systems. The BDM400 range of intelligent paging microphones is designed to provide a wide variety of features to suit any installation. There are six microphones available in the range one-zone to 32-zone.Key FeaturesAvailable in six versions - from one-zone up to 32-zone.Communicate with the main control system via an RS485 link.A standard RJ45 CAT5 network cable is used to carry both audio and serial data.Microphones can be linked together via wall sockets - product code BMS8 and connected to a single input at the control rack.The BDM401 can also be operated as a parallel microphone. This option is selected internally by jumpers. Factory setting is for serial operation.Ergonomic design with all buttons and indicators mounted behind a stylish overlay that allows zone button labels to be inserted and protected.The dynamic cardoid microphone capsule can be set for either monitored or unmonitored use during configuration.Zone status indicators show if a zone is currently selected or in use.All call paging except BDM401.Speak now indicator to show the user when a pre-announcement chime has finished.Simple bar graph display shows the user the current speech volume ensuring a clear announcement is made.Data and DC indicators to show the unit is functioning correctly.Zonal fault indicators are included to show when a fault is evident on the system.Fault accept button.Option to fit flip-top switches to enable DVA digital voice announcement messages to be broadcast.

GBP 1146.70
1

Baldwin Boxall 32 Zone Intelligent Paging Microphone BDM432

Baldwin Boxall 32 Zone Intelligent Paging Microphone BDM432

Baldwin Boxall 32 Zone Intelligent Paging Microphone BDM432BDM400 microphones for public address and voice alarm systems. The BDM400 range of intelligent paging microphones is designed to provide a wide variety of features to suit any installation. There are six microphones available in the range one-zone to 32-zone.Key FeaturesAvailable in six versions - from one-zone up to 32-zone.Communicate with the main control system via an RS485 link.A standard RJ45 CAT5 network cable is used to carry both audio and serial data.Microphones can be linked together via wall sockets - product code BMS8 and connected to a single input at the control rack.The BDM401 can also be operated as a parallel microphone. This option is selected internally by jumpers. Factory setting is for serial operation.Ergonomic design with all buttons and indicators mounted behind a stylish overlay that allows zone button labels to be inserted and protected.The dynamic cardoid microphone capsule can be set for either monitored or unmonitored use during configuration.Zone status indicators show if a zone is currently selected or in use.All call paging except BDM401.Speak now indicator to show the user when a pre-announcement chime has finished.Simple bar graph display shows the user the current speech volume ensuring a clear announcement is made.Data and DC indicators to show the unit is functioning correctly.Zonal fault indicators are included to show when a fault is evident on the system.Fault accept button.Option to fit flip-top switches to enable DVA digital voice announcement messages to be broadcast.

GBP 1404.35
1

Baldwin Boxall 1 Zone Intelligent Paging Microphone BDM401

Baldwin Boxall 1 Zone Intelligent Paging Microphone BDM401

Baldwin Boxall 1 Zone Intelligent Paging Microphone BDM401BDM400 microphones for public address and voice alarm systems. The BDM400 range of intelligent paging microphones is designed to provide a wide variety of features to suit any installation. There are six microphones available in the range one-zone to 32-zone.Key FeaturesAvailable in six versions - from one-zone up to 32-zone.Communicate with the main control system via an RS485 link.A standard RJ45 CAT5 network cable is used to carry both audio and serial data.Microphones can be linked together via wall sockets - product code BMS8 and connected to a single input at the control rack.The BDM401 can also be operated as a parallel microphone. This option is selected internally by jumpers. Factory setting is for serial operation.Ergonomic design with all buttons and indicators mounted behind a stylish overlay that allows zone button labels to be inserted and protected.The dynamic cardoid microphone capsule can be set for either monitored or unmonitored use during configuration.Zone status indicators show if a zone is currently selected or in use.All call paging except BDM401.Speak now indicator to show the user when a pre-announcement chime has finished.Simple bar graph display shows the user the current speech volume ensuring a clear announcement is made.Data and DC indicators to show the unit is functioning correctly.Zonal fault indicators are included to show when a fault is evident on the system.Fault accept button.Option to fit flip-top switches to enable DVA digital voice announcement messages to be broadcast.

GBP 596.03
1

Baldwin Boxall 4 Zone Intelligent Paging Microphone BDM404

Baldwin Boxall 4 Zone Intelligent Paging Microphone BDM404

Baldwin Boxall 4 Zone Intelligent Paging Microphone BDM404BDM400 microphones for public address and voice alarm systems. The BDM400 range of intelligent paging microphones is designed to provide a wide variety of features to suit any installation. There are six microphones available in the range one-zone to 32-zone.Key FeaturesAvailable in six versions - from one-zone up to 32-zone.Communicate with the main control system via an RS485 link.A standard RJ45 CAT5 network cable is used to carry both audio and serial data.Microphones can be linked together via wall sockets - product code BMS8 and connected to a single input at the control rack.The BDM401 can also be operated as a parallel microphone. This option is selected internally by jumpers. Factory setting is for serial operation.Ergonomic design with all buttons and indicators mounted behind a stylish overlay that allows zone button labels to be inserted and protected.The dynamic cardoid microphone capsule can be set for either monitored or unmonitored use during configuration.Zone status indicators show if a zone is currently selected or in use.All call paging except BDM401.Speak now indicator to show the user when a pre-announcement chime has finished.Simple bar graph display shows the user the current speech volume ensuring a clear announcement is made.Data and DC indicators to show the unit is functioning correctly.Zonal fault indicators are included to show when a fault is evident on the system.Fault accept button.Option to fit flip-top switches to enable DVA digital voice announcement messages to be broadcast.

GBP 619.62
1

Testifire 6001-001 Smoke and Heat Detector Test and Removal Kit - 6 Metres 20 Feet

Testifire 6001-001 Smoke and Heat Detector Test and Removal Kit - 6 Metres 20 Feet

Testifire 6001-001 Smoke and Heat Detector Test and Removal Kit - 6 Metres 20 FeetNow Including High Capacity Battery BatonsTestifire 1000 Series is the worlds first multi-stimulus detector tester for smoke heat and multi-stimulus detectors. Both smoke and heat stimuli are created in a single test unit and delivered individually or - for the first time - simultaneously in whichever combination are required.Testifire does this without using pressurised cans of gas or other hazardous goods. Stimuli Smoke and Heat are generated at the time of test using safe and patented processes fuelled by replaceable capsules.The new SOLO770 Battery Baton is a higher capacity product 3000mAh. It allows greater efficiency both in the field and on-site as it gives more tests per battery for the same charge time as before but provided by the new SOLO727 Battery Charger.The SOLO727 charger has also been improved and while it provides the same functionality as before it is now capable of enabling fast charging of the new higher capacity battery batons from both mains power and in-vehicle outlets.Features BenefitsTesting with one tool is faster and more productiveLess tools and equipment to carry aroundAllows testing and removal of detectors up to 6 metres 20 feet in heightCombined stimuli delivers quicker activation times for combination detectorsUnique Clearing Cycle provides rapid detector reset with no repeat alarmsTest times reduced by as much as 66 saving labourFully reverse compatible with the Solo range of poles battery batons and chargers.Ideal in any application Land Air and MarineA must have addition to any Professional Engineers Tool SuiteReduced carriage and shipping costs - no pressurised cans of gasReduced Test Stimuli Re-stocking and freight costs - no pressurised cans of gasTestifire 6001 - 001 Smoke and Heat Detector Testing and Removal Kit Includes1 x Testifire 1000-001 Head Unit inside the 1000-001 box it will also include 1 x TS3-001 Smoke Capsule 1 x Solo 770-001 Battery Baton option to buy second baton in the drop-down box and 1 x Solo 727-001 Multi Voltage Fast Charger1 x Solo 100-001 Fibreglass Telescopic Access Pole 4.5 metres 15 feet1 x Solo 200-001 Universal Detector Removal Tool1 x Solo 610-001 Protective Carrying Storage Bag

GBP 2208.17
1

Scope TLINKAC Telemetry System for One-way Link DL3-05-AC amp RX10SAC

Scope TLINKAC Telemetry System for One-way Link DL3-05-AC amp RX10SAC

Scope TLINKAC Telemetry System for One-way Link DL3-05-AC RX10SACT-Link takes a 5-zone DigiLink transmitter and combines it with a RX10 receiver and two aerials to produce an off the shelf one-way radio link between fire or intruder panels. The transmitter has five input zones which can be triggered by volts-free opening or closing contacts or can be configured to accept voltage applied or voltage removed.The system is supplied pre-configured to operate change-of-state so a closing contact at the transmitter sends a signal to the receiver to activate the corresponding zone output relay. When the transmitter input is de-activated the relay is deactivated so the output actually follows the input. A programming kit is available if you need to reconfigure the system. Additional transmitters and receivers can be added when needed.This can simply be achieved by installing Digilink transmitters and receivers adjacent to the fire or security panels where their relay contacts can be hard wired into the output inputs of the panel in order to provide wireless alarm signals between buildings. For roaming fire marshals and security personnel the serial output of the receiver can be connected to the Scope Connexions Range of paging transmitters in order to send pre-programmed text messages to pocket worn pagers.It is also possible to connect the printer output of analogue addressable panel to a serial port of the Connexions transmitter in order to transmit real time panel messages to the pagers thus saving valuable time by not having to view the message at the panel. The same format could also be deployed for access control plant monitoring lone worker and care home applications where staff has to be made aware of situations arising from automated or manual inputs.

GBP 862.99
1

Scope TLINK12V Telemetry System for One-way Link DL3-05-12V amp RX10SDC

Scope TLINK12V Telemetry System for One-way Link DL3-05-12V amp RX10SDC

Scope TLINK12V Telemetry System for One-way Link DL3-05-12V RX10SDCT-Link takes a 5-zone DigiLink transmitter and combines it with a RX10 receiver and two aerials to produce an off the shelf one-way radio link between fire or intruder panels. The transmitter has five input zones which can be triggered by volts-free opening or closing contacts or can be configured to accept voltage applied or voltage removed.The system is supplied pre-configured to operate change-of-state so a closing contact at the transmitter sends a signal to the receiver to activate the corresponding zone output relay. When the transmitter input is de-activated the relay is deactivated so the output actually follows the input. A programming kit is available if you need to reconfigure the system. Additional transmitters and receivers can be added when needed.This can simply be achieved by installing Digilink transmitters and receivers adjacent to the fire or security panels where their relay contacts can be hard wired into the output inputs of the panel in order to provide wireless alarm signals between buildings. For roaming fire marshals and security personnel the serial output of the receiver can be connected to the Scope Connexions Range of paging transmitters in order to send pre-programmed text messages to pocket worn pagers.It is also possible to connect the printer output of analogue addressable panel to a serial port of the Connexions transmitter in order to transmit real time panel messages to the pagers thus saving valuable time by not having to view the message at the panel. The same format could also be deployed for access control plant monitoring lone worker and care home applications where staff has to be made aware of situations arising from automated or manual inputs.

GBP 764.71
1

Fireclass DB3B Flameproof Horn Sounder - High Power

Fireclass DB3B Flameproof Horn Sounder - High Power

Fireclass DB3BDGD048N2BNRFC DB3B Flameproof Horn Sounder High Power Explosion Proof 122dB 1mThe DB3B is a high-power explosion proof sounder introduced as a replacement for the current DB3 with improved functionality and performance.Certified for use in a wide range of temperatures from -55C to 70C the Ex enclosure is manufactured from GRP with a rugged thermoplastic flare providing a corrosion free and aesthetically pleasing product.Capable of producing 122dB 1m and with a range of pre-recorded tones the DB3B includes an integral volume control which is ideal when a lower output is required.The unit is provided with versatile control options allowing compatibility with a wide range of control methods and PLCs.The standard DC unit provides 3 tone stages each stage has 28 tones available which can be independently selected. The unit can be controlled by reversing the polarity of the power supply 2 stage or providing a common negative and switching between multiple positive supplies. The DB3B proves its versatility by additionally being able to work with a common positive supply and switching the negatives. The tone stages of the DB3B can also be controlled via voltage free contacts provided by a control panel.Key FeaturesEx d Ex de IICIIIC T4T5T6ATEX certifiedIECEx certifiedUL certified for USA and Canada Class I Div 2 Groups A-D Class I Zone 1 Ex d IICAEx d IIC Gb Class II Div 2 Groups F G Zone 21 AEx tb IIIC Class III Div. 1TR CU certifiedCQST certifiedCCOE certifiedChinese Compulsory Certification for Fire systems CCCF certifiedINMETRO certifiedSIL 1 certifiedCSFM certifiedUp to 122dB output 1mIntegral volume control28 tones user selectable3 stage unit remotely switchableTones can be programmed to customers specificationDC supply voltage between 12V and 48VEx enclosure - glass reinforced polyesterFlare - high impact thermoplastic polyester

GBP 896.45
1

Scope TLINKLT Telemetry System for One-way Link DL3-05-12V amp RX10LT

Scope TLINKLT Telemetry System for One-way Link DL3-05-12V amp RX10LT

Scope TLINKLT Telemetry System for One-way Link DL3-05-12V RX10LTT-Link takes a 5-zone DigiLink transmitter and combines it with a RX10 receiver and two aerials to produce an off the shelf one-way radio link between fire or intruder panels. The transmitter has five input zones which can be triggered by volts-free opening or closing contacts or can be configured to accept voltage applied or voltage removed.The system is supplied pre-configured to operate change-of-state so a closing contact at the transmitter sends a signal to the receiver to activate the corresponding zone output relay. When the transmitter input is de-activated the relay is deactivated so the output actually follows the input. A programming kit is available if you need to reconfigure the system. Additional transmitters and receivers can be added when needed.This can simply be achieved by installing Digilink transmitters and receivers adjacent to the fire or security panels where their relay contacts can be hard wired into the output inputs of the panel in order to provide wireless alarm signals between buildings. For roaming fire marshals and security personnel the serial output of the receiver can be connected to the Scope Connexions Range of paging transmitters in order to send pre-programmed text messages to pocket worn pagers.It is also possible to connect the printer output of analogue addressable panel to a serial port of the Connexions transmitter in order to transmit real time panel messages to the pagers thus saving valuable time by not having to view the message at the panel. The same format could also be deployed for access control plant monitoring lone worker and care home applications where staff has to be made aware of situations arising from automated or manual inputs.

GBP 660.82
1

Patol 710-020 Controller 5020 for Spares Only

Patol 710-020 Controller 5020 for Spares Only

Patol 710-020 Controller 5020 for Spares Only - for use with Sensor Models 5010 5012 5712The 5020 controller is directly connected to the sensor. A series of user programmable DIL switches allows option selection including detector sensitivity settings automanual reset sequence selection and single coincidence voting from the four individual internal detection channels for the alarm trip and shutdown outputs.The Sensor Unit is located above the materials transit path e.g. conveyor by means of the adjustable mounting bracket and aligned such that the monitored hazard passes through the sensors field of view. The height and angle of the sensor determine the width of the monitored path.The Type 5020 Control Unit provides various indications and controls related to infra-red detection alarms and fault monitoring.The control module is easily de-mountable from the housing and connects to the sensor by means of a ten core screened shielded cable. These terminations together with supply and output contact connections are via two part screw terminals thus enabling installation of the housing and site cables prior to fitment of the module. The housing has a high level of ingress protection IP67.The unit incorporates a user programmable DIL switch to set the options which include detector sensitivity setting automanual reset sequence selection and one-shot coincidence voting for the alarm and tripshutdown outputs.The sensor air pressure and signal cable connections are fault monitoredfail safe. The unit incorporates an aux. fault input common fault output contact.The 5020 Controller also includes LED indication of the four detector channels along with LED indication and relay outputs for Alarm Trip and Fault.The controller can be provided in an optional outer control panel together with power supplies battery chargers DIN rail terminals as required.Key FeaturesMaterial Fan Case - White Polyester Resin Impellors - Aluminium 1200 H14IP Rating IP44Weight 8.5Kg

GBP 2076.48