65 results (0,14471 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Ziton FD310 End-to-End Beam Detector 5 to 120m

Ziton FD310 End-to-End Beam Detector 5 to 120m

Ziton FD310 End-to-End Beam Detector 5 to 120mOptical beam smoke detector consists of separate transmitter and receiver heads and a low level controller.The FD310 End to End infrared Optical Beam Smoke Detector OBSD has been designed using the latest optical technology incorporating modern industrial electronic and software techniques. This detector offers cost effective protection of large open area spaces with high ceilings. It is also very suited to applications where access to ceiling mounted smoke detectors presents practical difficulties.The system comprises a modern looking Transmitter head which emits a narrow beam of infra-red light to an associated Receiver head with a compact Low Level Controller. Once smoke crosses through and thus obscures the IR beam path the signal strength at the Receiver drops below a pre-set level which in turn results in an alarm condition. Both the detector heads Transmitter and Receiver have integrated alignment thumbwheels for ease of alignment. Using these thumbwheels provides a smooth and repeatable alignment process. The detector heads have up to 10 degrees of adjustment in both planes. For further adjustment a bespoke Adjustment Bracket is available which offers up to 180 degrees movement in both planes as well as a full 360-degree rotation.The FD310 has been designed so that it can be installed by one operator with its laser assisted alignment method combined with easy to use alignment LEDs offering a visual feedback. Integrated laser alignment aid can be activated at the Controller or at the Receiver head.The low level Controller incorporates a LCD display which offers a full icon-based easy-to-use interface unit. This Controller enables ease of commissioning testing and maintenance of the beam detection system. During commissioning the detector sensitivity and fire thresholds can be selected along with the user variable time to fire and time to fault settings.Range 5 to 120m integral laser alignment controller can support 2 pairs of transmitter and receivers additional pairs are available FD310H.Key FeaturesSeparate Transmitter and Receiver HeadsRange 5 to 120 metres configurable per set of DetectorsIntegral Laser Alignment in Receiver2-wire Interface between Controller and ReceiverSingle and Twin Detector optionsSeparate Fire and Fault Relays per DetectorLow Level Controller with LCD displayProgrammable Sensitivity and Fire ThresholdAutomatic Gain Control AGC for drift compensationFirst Fix concept for Transmitter Receiver and ControllerMultiple cable gland knockouts for ease of wiringOptional Transmitter powering from ControllerSupply voltage 12-36VDCCurrent Controller 14mA per transmitter head 8mAFire and Fault relays per detector head - rated 2A 30VDCDetector head dimensions per transmitter and receiver unit mm 74w x 74h x 161dController dimensions mm 203w x 124h x 73d

GBP 947.02
1

Ziton ZP886R-TSKIT ZP7 Series Intelligent Addressable Manual Call Point cw Skirt

Ziton ZPR868-C 868Mhz Radio Cluster Communicator RCC 24Vdc

Ziton ZPR868-C 868Mhz Radio Cluster Communicator RCC 24Vdc

Ziton ZPR868-C 868Mhz Radio Cluster Communicator RCC 24VdcThe ZPR868-C is a 24VDC powered wireless cluster communicator for interfacing Ziton wireless 868 MHz fire alarm devices into a ZP fire alarm system. It enables these wireless devices to be controlled directly from the ZP7 compatible CIE and provides a seamless interface between wireless devices and the CIE.System designA cluster communicator comprises of a radio transceiver capable of communicating with up to 31 wireless devices. Every cluster communicator communicates directly to a ZPR868-H hub or should direct communication not be possible via another cluster communicator with up to 4 hops to the hub. This allows for full meshed networked wireless systems with multiple redundant wireless communication parts as well as longer wireless communication ranges when that is required on large sites.Seamless addition of wireless devicesEvery wireless device controlled through a cluster communicator has its own unique address with which the main fire alarm control panel communicates with it providing the same system capabilities as directly wired devices. A full range of wireless detection and alarm devices is available including multi-sensors capable of dual sensing heat and smoke smoke only or heat only configurations manual call points notification devices sounders beacons as well as inputoutput units.Full flexibilityWireless devices are featured in many fire detection and alarm systems specified where the installation of hard wiring would be difficult or impossible to complete decorative finishes to the interior of the protected building preclude wiring runs or where the time scales to complete installation are minimal. Cluster communicators allow the system designer full flexibility in selecting the locations of wireless devices anywhere in the system or even allow all the filed devices in system to be wireless up to 508 devices per CIE or 127 devices per loop.Key Features24VDC supply2-Way communication with up to 31 wireless devicesDiversity transceivers allow maximum operational rangeVariable power outputETSI 300-220 approvedEN54-4 18 25 complaint and CPR certified

GBP 364.58
1

Ziton ZPR868-CM Protocol 868Mhz Radio Cluster Communicator Mains Powered

Ziton ZPR868-CM Protocol 868Mhz Radio Cluster Communicator Mains Powered

Ziton ZPR868-CM Protocol 868Mhz Radio Cluster Communicator Mains PoweredThe ZPR868-CM is a mains powered wireless cluster communicator for interfacing Ziton wireless 868 MHz fire alarm devices into a ZP fire alarm system. It enables these wireless devices to be controlled directly from the ZP7 compatible CIE and provides a seamless interface between wireless devices and the CIE.System designA cluster communicator comprises of a radio transceiver capable of communicating with up to 31 wireless devices. Every cluster communicator communicates directly to a ZPR868-H hub or should direct communication not be possible via another cluster communicator with up to 4 hops to the hub. This allows for full meshed networked wireless systems with multiple redundant wireless communication parts as well as longer wireless communication ranges when that is required on large sites.Seamless addition of wireless devicesEvery wireless device controlled through a cluster communicator has its own unique address with which the main fire alarm control panel communicates with it providing the same system capabilities as directly wired devices. A full range of wireless detection and alarm devices is available including multi-sensors capable of dual sensing heat and smoke smoke only or heat only configurations manual call points notification devices sounders beacons as well as inputoutput units.Full flexibilityWireless devices are featured in many fire detection and alarm systems specified where the installation of hard wiring would be difficult or impossible to complete decorative finishes to the interior of the protected building preclude wiring runs or where the time scales to complete installation are minimal. Cluster communicators allow the system designer full flexibility in selecting the locations of wireless devices anywhere in the system or even allow all the filed devices in system to be wireless up to 508 devices per CIE or 127 devices per loop.Key FeaturesMains supply with battery backup2-Way communication with up to 31 wireless devicesDiversity transceivers allow maximum operational rangeVariable power outputETSI 300-220 approvedEN54-4 18 25 complaint and CPR certified

GBP 364.58
1

Ziton ZP886R-RMKIT ZP7 Series Intelligent Addressable Manual Call Point - Recess Mount

Ziton FD310H - Additional Detector Pair 5 - 120m for FD310

Ziton FD310H - Additional Detector Pair 5 - 120m for FD310

ZitonFD310H - Additional Detector Pair 5 - 120m for FD310The FD310 End to End infrared Optical Beam Smoke Detector OBSD has been designed using the latest optical technology incorporating modern industrial electronic and software techniques. This detector offers cost effective protection of large open area spaces with high ceilings. It is also very suited to applications where access to ceiling mounted smoke detectors presents practical difficulties.OperationThe system comprises a modern looking Transmitter head which emits a narrow beam of infra-red light to an associated Receiver head with a compact Low Level Controller. Once smoke crosses through and thus obscures the IR beam path the signal strength at the Receiver drops below a preset level which in turn results in an alarm condition. Both the detector heads Transmitter and Receiver have integrated alignment thumbwheels for ease of alignment. Using these thumbwheels provides a smooth and repeatable alignment process. The detector heads have up to 10 degrees of adjustment in both planes. For further adjustment a bespoke Adjustment Bracket is available which offers up to 180 degrees movement in both planes as well as a full 360-degree rotation.The FD310 has been designed so that it can be installed by one operator with its laser assisted alignment method combined with easy to use alignment LEDs offering a visual feedback. Integrated laser alignment aid can be activated at the Controller or at the Receiver head.The low level Controller incorporates a LCD display which offers a full icon-based easy-to-use interface unit. This Controller enables ease of commissioning testing and maintenance of the beam detection system. During commissioning the detector sensitivity and fire thresholds can be selected along with the user variable time to fire and time to fault settings.Key FeaturesSeparate Transmitter and Receiver HeadsRange 5 to 120 metres configurable per set of DetectorsIntegral Laser Alignment in Receiver2-wire Interface between Controller and ReceiverSingle and Twin Detector optionsSeparate Fire and Fault Relays per DetectorLow Level Controller with LCD displayProgrammable Sensitivity and Fire ThresholdAutomatic Gain Control AGC for drift compensationFirst Fix concept for Transmitter Receiver and ControllerMultiple cable gland knockouts for ease of wiringOptional Transmitter powering from Controller

GBP 789.20
1

Ziton Conventional Supervised Relay Board Panel Accessory - 2010-1-SB

Ziton Conventional Fire and Extinguishing Panel EN12094 3 Zone ZP1-X3E-03

Ziton Conventional Fire and Extinguishing Panel EN12094 3 Zone ZP1-X3E-03

Ziton Conventional Fire and Extinguishing Panel EN12094 3 Zone ZP1-X3-03ZP1 fire control panels offer state of the art architecture in configurations that deliver an uncomplicated solution for small to mid-sized conventional applications. They feature an attractive contemporary design that fits with any decor. The gently curved door front offers a distinctive flair. Operator controls are inset in a striking blue lexan. With support for multiple lines of conventional detectors and accessories these quick-to-configure systems offer versatility that benefits building owners and installationmaintenance companies alike.The ZP1-X3 is a conventional fire alarm and extinguishing control panel. It is supplied in local language with 3 fire zones that support up to 32 devices per zone. These zones may be configured for extinguishing in single zone or double zone configuration in any combination of zones. In addition the panel offers supervised outputs for first stage notification second stage notification as well as optical warning indicators and actuator activation. Standard relay outputs are provided for EN54 compliance and system status notification as well as multiple inputs for system control.The panels support 2 types of auxiliary relay boards one with 4 standard relays and one with 4 supervised relays. With these boards the panel outputs may be expanded with up to 16 additional outputs.The ZP1-X3E supports class A redundant ring and B standard bus networking with up to 32 nodes including conventional and addressable panels and repeaters via an optional network interface. This allows full remote control and inputs to and from other nodes in the system providing superior flexibility in system organisation and planning.Key FeaturesModern elegant designEasy removable parts for quick and easy installationNormal head-out supervision support per zoneThree detection zones Single zone double zone or any combination of zones configurable for release6 Pre-configured relays and 8 supervised inputs for extinguishing controlConfigurable fire routing sounder extinguishing reset and door monitoring delaysConfigurable Hold Mode type-A or type-B Sounders configurable for pulsing or continuous operationExtinguishing agent flow confirmationContinuous or resettable 24 VDC auxiliary suppliesAuxiliary standard supervised relay output supportDefault support for special functions such as - EN54 compliant user access levels - Basic Advanced level configuration - mixed zones - front panel diagnostics with test disable control - one-man walk testRedundant networking to ZP1 conventional and ZP2 addressable nodesIntrinsically safe and EN54-13 zone support

GBP 376.19
1

Ziton AD105SS-0100 Alarmline 105 Degree Alarm Temperature Digital Sensor Cable PVC and Stainless Steel

Ziton AD68-0100 Alarmline 68 Degree Alarm Temperature Digital Sensor Cable PVC

Ziton AD88N-0100 Alarmline 88 Degree Alarm Temperature Digital Sensor Cable Nylon

Ziton AD88-1000 Alarmline 88 Degree Alarm Temperature Digital Sensor Cable PVC

Ziton AD105-0100 Alarmline 105 Degree Alarm Temperature Digital Sensor Cable PVC

Ziton AD105N-0100 Alarmline 105 Degree Alarm Temperature Digital Sensor Cable Nylon

Ziton AD88SS-0100 Alarmline 88 Degree Alarm Temperature Digital Sensor Cable PVC and Stainless Steel

Ziton AD185N-0100 Alarmline 185 Degree Alarm Temperature Digital Sensor Cable

Ziton AD88-0500 Alarmline 88 Degree Alarm Temperature Digital Sensor Cable PVC

Ziton AD68-1000 Alarmline 68 Degree Alarm Temperature Digital Sensor Cable PVC

Ziton AD88N-0500 Alarmline 88 Degree Alarm Temperature Digital Sensor Cable Nylon

Ziton AD105SS-0500 Alarmline 105 Degree Alarm Temperature Digital Sensor Cable PVC and Stainless Steel

Ziton AD105-0500 Alarmline 105 Degree Alarm Temperature Digital Sensor Cable PVC

Ziton AD185N-0500 Alarmline 185 Degree Alarm Temperature Digital Sensor Cable

Ziton AD88P-0100 Alarmline 88 Degree Alarm Temperature Digital Sensor Cable PVC and Poly

Ziton AD88N-1000 Alarmline 88 Degree Alarm Temperature Digital Sensor Cable Nylon