227 results (0,13951 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Zeta ZT-ST5-5 3V Standalone Smoke Detector 5 Year Life

Zeta ZT-TH5 Zeta 9V Standalone Heat Detector 1 Year Life

Zeta ZT-MAINS-5 Mains Photoelectric Smoke Alarm with 9V Battery Back-Up

Zeta ZT-CP4ADSTD Zeta Mark 1 Protocol Manual Call Point Red

Zeta DPTA-KIT1 Disabled Toilet Alarm - 1 Zone Kit

Zeta ZAIO230 Mains IO 1 Channel InputOutput Module - Fyreye MKII Protocol

Zeta ZAIO230 Mains IO 1 Channel InputOutput Module - Fyreye MKII Protocol

Zeta ZAIO230 Mains IO 1 Channel InputOutput Module - Fyreye MKII Protocol -8A 230V ACThe Mains IO Modules are fully monitored loop powered devices which permit the interfacing of third-party equipment with the Fire Alarm Control panel using normally open dry contact connections.The connection to the input is monitored for fault open or short circuit and Alarm conditions.The interface is used to monitor the contacts of an external system which must be interfaced to the Fire Alarm System for example a Flow Switch in a sprinkler system to indicate if the sprinklers have been activated or extinguishant level monitoring in Gas Extinguishing systems etc.Module is provided with a loop short-circuit isolator and with a voltage free single pole change over mains rated output. The output relay is always powered directly from the detection loop. It is not required to use an external 24V DC power supply. Relay operation is confirmed by an on-board red LED.An 8-way D.I.L switch is provided to configure the modules address. This value can be set in the range 1 to 125.The following programmable functions are available Input Activation Mode Delayed Input Alarm Activation Output Delayed Activation.The Simplicity CO 8 range is designed to detect monitor CO concentrations in places such as warehouses car parks tunnels and enclosed buildings where forklifts cars and delivery trucks can produce deadly amounts of carbon monoxide in high traffic areas Carbon Monoxide can accumulate in these areas and can be a serious safety and health concern.Key FeaturesFast Activation ResponseLoop PoweredFive Status LEDs providedLow Power ConsumptionModule features an integral short-circuit loop isolatorSingle mains rated relay contact

GBP 57.38
1

Zeta SMART1 SmartConnect Touchscreen 1 Loop Addressable Fire Alarm Panel

Zeta IN1 Infinity 1 Zone Conventional Fire Alarm Panel

Zeta MKII-AHFI Fyreye MKII Addressable Fixed Heat Detector with Built In Isolator

Zeta ID2REPM Infinity ID2 Intelligent 2 Wire Full Function Repeater in Metal Enclosure

Zeta ID2REPM Infinity ID2 Intelligent 2 Wire Full Function Repeater in Metal Enclosure

Zeta ID2REPM Infinity ID2 Intelligent 2 Wire Full Function Repeater in Metal EnclosureZeta Alarm Systems is proud to introduce the most advanced 2 wire system on the market. We can now provide a system that gives all of the benefits associated with a 2 Wire installation less cable quicker installation cost savings on labourproduct and has the facility to I.D. the devices.The system is built on the proven communication protocol developed by Zeta Alarm Systems and shares the same platform as our largest most powerful system.The ID2 can be used for new installations as a retrofit for any conventional system or as a replacement for existing 2 wire systems when the extra features are deemed to be desirablenecessary. This is possible because the ID2 devices sit on radial circuits thus making it easy to upgrade a system with the facility to I.D. devices without the need to re-wire.Infinity ID2 Full Function Repeater Panel can be programmed to act as fully functional ability to silencereset or passive shows alarm info only. The panel includes zonal LEDs and a LCD display.4 cores are required from ID2 panel 2 data 2 power. It can powered from 24V auxiliary PSU in the ID2 panel.Key FeaturesThe system meets the full requirements of BSEN5839 parts 1 and 6.The control panel has been designed to meet EN54 parts 2 and 4.Each device can be uniquely identified by the panelDevice Count VerificationAlarm Verification2048 Event HistoryID2 Smartphone App available for iOS and AndroidCable Break protectionCable Short Circuit ProtectionIncludes zonal LEDs and LCD display4 cores required from ID2 panel 2 data 2 powerCan powered from 24V auxiliary PSU in the ID2 panel

GBP 450.17
1

Zeta SMART1M SmartConnect Touchscreen 1 Loop Addressable Fire Alarm Panel cw Metal Enclosure

Zeta GA-300.E01.ZETA Analogue Gas Controller 1 Detector

Zeta MKII-AHRI Fyreye MKII Addressable Rate of Rise Heat Detector with Built In Isolator

Zeta ID22M Infinity ID2 Intelligent 2 Wire 2 Zone Fire Panel in Metal Enclosure

Zeta ID24M Infinity ID2 Intelligent 2 Wire 4 Zone Fire Panel in Metal Enclosure

Zeta ZT-CP4ADWPPLUS Zeta Addressable CP4 Manual Call Point In Outdoor Tamperproof Housing

Zeta MKII-AOPI Fyreye MKII Addressable Optical Smoke Detector With Built In Isolator

Zeta ID28M Infinity ID2 Intelligent 2 Wire 8 Zone Fire Panel in Metal Enclosure

Zeta ID28M Infinity ID2 Intelligent 2 Wire 8 Zone Fire Panel in Metal Enclosure

Zeta ID28M Infinity ID2 Intelligent 2 Wire 8 Zone Fire Panel in Metal EnclosureZeta Alarm Systems is proud to introduce the most advanced 2 wire system on the market. We can now provide a system that gives all of the benefits associated with a 2 Wire installation less cable quicker installation cost savings on labourproduct and has the facility to I.D. the devices.The system is built on the proven communication protocol developed by Zeta Alarm Systems and shares the same platform as our largest most powerful system.The ID2 can be used for new installations as a retrofit for any conventional system or as a replacement for existing 2 wire systems when the extra features are deemed to be desirablenecessary. This is possible because the ID2 devices sit on radial circuits thus making it easy to upgrade a system with the facility to I.D. devices without the need to re-wire.Key FeaturesThe system meets the full requirements of BSEN5839 parts 1 and 6.The control panel has been designed to meet EN54 parts 2 and 4.Each device can be uniquely identified by the panelDevice Count VerificationAlarm Verification2048 Event HistoryID2 Smartphone App available for iOS and AndroidCable Break protectionCable Short Circuit ProtectionOne man walk test facilityAuto configuration for easy set upSafer than a traditional 2 wireconventional system as it tells you exactly where the event is - no time wasted searching a whole zone

GBP 642.60
1

Zeta MKII-AOPIB Fyreye MKII Addressable Optical Smoke Detector With Built In Isolator - Black

Zeta S64COM Simplicity CO 64 Addressable CO Panel - 4 Zone 64 Device in Metal Enclosure

Zeta S64COM Simplicity CO 64 Addressable CO Panel - 4 Zone 64 Device in Metal Enclosure

Zeta S64COM Simplicity CO 64 Addressable CO Panel - 4 Zone 64 Device in Metal EnclosureThe Simplicity CO system is a self-conditioned controller with a capacity to handle up to 110 CO monitors which are divided to 8 monitoring zones.Each Zone will permanently display on the Liquid Crystal Display LCD the highest concentration of CO in that zone in PPM Particles Per Million. This monitored value is updated every 10 seconds. The system will allow up to 2 interface modules ZIOUI-230 which are programmed to initiate a signal to Ventilation equipment to operate at pre-determined levels of concentration. Should the CO concentration keep rising while the Ventilation is still on an alarm is raised at a pre-determined level.The Simplicity CO system is ideal forUnderground car parking facilitiesWarehouses where non-electric fork lift vehicles are usedTunnelsFactoriesBoiler Rooms etcKey FeaturesAlarm Output 2 x 150mA 24 VdcPanel Size mm 370W x 311H x 113DSpace for Batteries Up to 2 x 7.0 AH SLA BatteriesHow is CO GeneratedCarbon Monoxide is a by-product of combustion. Any fuel burning appliance vehicle tool or other device has the potential to produce dangerous levels of Carbon Monoxide.The Simplicity CO 8 system is designed to detect monitor CO concentrations in places such as warehouses car parks tunnels and enclosed buildings where forklifts cars and delivery trucks can produce deadly amounts of carbon monoxide in high traffic areas Carbon Monoxide can accumulate in these areas and can be a serious safety and health concern.What is the Simplicity COThe Simplicity CO system was designed to be simple to use addressable carbon monoxide detection and ventilation system capable of detecting low concentrations of CO and automatically starting the buildings ventilation fans. Its features includeTrue analogue addressable systemEconomical 2 wire installationCan view the PPM reading of every detectorEach detector can be given a 20-character label to ease device identification optional.Loop of 126 devices divided into 8 zonesContinuously displays the maximum reading in each zoneOption for 2 ventilation relays per zone for systems with 2 speed fansZonal or common ventilation optionsEasy to use ventilation level selection Battery backup enables the system to give an alarm warning in the case of mains power failureSystem programming is determined by detector relay address settingsSuitable for small and large installationsDesigned Manufactured in the UKMeets latest low voltage directive CE marked

GBP 681.78
1

Zeta MKII-AOHI Fyreye MKII Addressable Combined Smoke amp Heat Detector with Built In Isolator