93 results (0,13931 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Wagner AD-05-1220 Basic Device - Top Sens - 3 Alarms Bargraph Per Detector

Wagner AD-05-1220 Basic Device - Top Sens - 3 Alarms Bargraph Per Detector

Wagner AD-05-1220 Basic Device - Top Sens - 3 Alarms Bargraph Per DetectorThe Titanus TopSens is an air sampling smoke detector with all the bells and whistles. It has all the features of the ProSens plus a network card slot to allow network capability via Ethernet SNMP connection. This premium product includes a bar graph to display smoke density levels in the event of fire.Thanks to a combination of highly sensitive HPLS optical technology and Logic Sens fire pattern recognition the Titanus TopSens combines maximum sensitivity and maximum security against false alarms in rooms as large as 5760 m. A second detector module can be used to create a dual detector dependency setup or to monitor a second area independently. Each detector module can be configured with up to three alarm levels. An additional connection socket makes parallel display possible.Key FeaturesThe Titanus TopSens features a graded alarm-activation concept with up to three alarms per detector module.Smoke levels can optionally be displayed on the unit as a bar graph.The pipe network can be configured with up to 1 x 100 or 2 x 72 air sampling points.An extensive range of DIN EN 54-20 certified accessories allow operators to tailor their systems to their individual needs.The systems modular design makes it a customisable and cost-effective solution.Versions for noise-critical areas 23 dB A and up or cold storage as low as -40 C are available as well.TianusPipeXpress Secure project planning and configuration is just five mouse clicks away.

GBP 2590.42
1

Wagner AD-05-0457 Basic Device Pro Sens 1 Alarm Per Detector

Wagner AD-05-0457 Basic Device Pro Sens 1 Alarm Per Detector

Wagner AD-05-0457 Basic Device Pro Sens 1 Alarm Per DetectorTITANUS PRO.SENS is a universal air sampling device suitable for a broad range of applications. The high degree of modularity of the device makes it possible to achieve a cost-effective solution customised to suit the specific needs of the customer. An additional price advantage comes with the optional equipping of the device with a second detector module.The base TITANUS PRO.SENS unit with 2 detector heads fittedTITANUS PRO.SENS 2 can be used for separate zone detection of a room and its equipment or configured as a double knock tripping system. Each detector is completely separate with no switching or leak between detection zones.Key FeaturesRobust Efficient High Pressure Light Source HPLS Detection TechnologyLOGICSENS Fire Pattern Recognition TechnologyFreezer Version Operates in -40Deg to 60DegC with No Heater Boxes RequiredA Powerful Efficient Aspirator Allowing up to 560m of PipeworkA BlowFree System for Programmed or Automated On-Demand Pipe ClearingModular Plug In Detector Heads for a Customised Cost Effective Solution MaintenanceDual Detector Ability Allows Separate Monitoring Reporting of Room Equipment with One UnitTime Saving Installation Commissioning Via Plug Play SetupLarge Capacity 3-Stage Filters with Selectable 1-15 Micron RatingsA Large Range of Fittings Pipework and Sampling PointsXP95 Interfacing to FireFinderTMand LoopSenseTM Fire Control PanelsFIP Bar Graph Display Module Available SmartGraphicsHD Display IntegrationCost Effective Solutions for Every Application Type

GBP 914.64
1

Wagner AD-05-3500 Device Base TITANUS MICROSENS

Wagner AD-05-3500 Device Base TITANUS MICROSENS

Wagner AD-05-3500 Device Base TITANUS MICROSENSTheWagner AD-05-3500 is a device which is used to house the Wagner Titanus MicroSens aspirating smoke detector.WAGNERs smallest air sampling smoke detector the TITANUSMICROSENS is designed for small to medium-sized areas up to 400 m in size. This economical air sampling smoke detector is ideal for use in hotel rooms offices and prison cells. The optional ROOMIDENT feature can localise fires within up to five rooms.The pint-sized TITANUSMICROSENSprovides a wealth of options. It can be configured to use a single primary alarm or a two-stage system pre-alarm and main alarm. Options include a bar graph displaying smoke density levelsanda parallel display connection. Thanks to PIPE.GUARD HPLS light technology and LOGICSENS this air sampling smoke detection system is both highly sensitive and secure against false alarms.Key FeaturesThe primary alarm can be set to sensitivity levels as high as 0.1 obs.m.This air sampling smoke detectors 40 to 50m-long pipe system can have up to eight air sampling points 5 with ROOMIDENT.The TITANUSMICROSENShas a wide range of options so it can be customised to any number of situations.A second detector module can be incorporated to create a dual detector dependency configuration.Special versions are available for deep-freeze facilities temperatures as low as -40 C and noise-critical areas to 23 dB A.The plug-and-play system makes the air sampling smoke detector quick and easy to install.Maintenance work can be performed without entering the protected area.

GBP 109.12
1

Wagner AD-10-5230 Detector Module TT for ProSensnet amp Silent

Wagner AD-05-4300 Detection Unit TITANUS MICROSENS - Basic Device

Wagner AD-05-4300 Detection Unit TITANUS MICROSENS - Basic Device

Wagner AD-05-4300 Detection Unit TITANUS MICROSENS - Basic DeviceWAGNERs smallest air sampling smoke detector the TITANUSMICROSENS is designed for small to medium-sized areas up to 400 m in size. This economical air sampling smoke detector is ideal for use in hotel rooms offices and prison cells. The optional ROOMIDENT feature can localise fires within up to five rooms.The pint-sized TITANUSMICROSENSprovides a wealth of options. It can be configured to use a single primary alarm or a two-stage system pre-alarm and main alarm. Options include a bar graph displaying smoke density levelsanda parallel display connection. Thanks to PIPE.GUARD HPLS light technology and LOGICSENS this air sampling smoke detection system is both highly sensitive and secure against false alarms.Key FeaturesThe primary alarm can be set to sensitivity levels as high as 0.1 obs.m.This air sampling smoke detectors 40 to 50m-long pipe system can have up to eight air sampling points 5 with ROOMIDENT.The TITANUSMICROSENShas a wide range of options so it can be customised to any number of situations.A second detector module can be incorporated to create a dual detector dependency configuration.Special versions are available for deep-freeze facilities temperatures as low as -40 C and noise-critical areas to 23 dB A.The plug-and-play system makes the air sampling smoke detector quick and easy to install.Maintenance work can be performed without entering the protected area.

GBP 801.89
1

Wagner AD-05-4000 Detection Unit TITANUS MICROSENS - Basic Device

Wagner AD-05-4000 Detection Unit TITANUS MICROSENS - Basic Device

Wagner AD-05-4000 Detection Unit TITANUS MICROSENS - Basic DeviceWAGNERs smallest air sampling smoke detector the TITANUSMICROSENS is designed for small to medium-sized areas up to 400 m in size. This economical air sampling smoke detector is ideal for use in hotel rooms offices and prison cells. The optional ROOMIDENT feature can localise fires within up to five rooms.The pint-sized TITANUSMICROSENSprovides a wealth of options. It can be configured to use a single primary alarm or a two-stage system pre-alarm and main alarm. Options include a bar graph displaying smoke density levelsanda parallel display connection. Thanks to PIPE.GUARD HPLS light technology and LOGICSENS this air sampling smoke detection system is both highly sensitive and secure against false alarms.Key FeaturesThe primary alarm can be set to sensitivity levels as high as 0.1 obs.m.This air sampling smoke detectors 40 to 50m-long pipe system can have up to eight air sampling points 5 with ROOMIDENT.The TITANUSMICROSENShas a wide range of options so it can be customised to any number of situations.A second detector module can be incorporated to create a dual detector dependency configuration.Special versions are available for deep-freeze facilities temperatures as low as -40 C and noise-critical areas to 23 dB A.The plug-and-play system makes the air sampling smoke detector quick and easy to install.Maintenance work can be performed without entering the protected area.

GBP 1420.31
1

Wagner AD-05-4020 Detection Unit TITANUS MICROSENS - Bar Graph

Wagner AD-05-4020 Detection Unit TITANUS MICROSENS - Bar Graph

Wagner AD-05-4020 Detection Unit TITANUS MICROSENS - Bar GraphWagner AD-05-4020 Titanus MicroSens Detection Unit Bar Graph Version - DM-TM-B-10WAGNERs smallest air sampling smoke detector the TITANUSMICROSENS is designed for small to medium-sized areas up to 400 m in size. This economical air sampling smoke detector is ideal for use in hotel rooms offices and prison cells. The optional ROOMIDENT feature can localise fires within up to five rooms.The pint-sized TITANUSMICROSENSprovides a wealth of options. It can be configured to use a single primary alarm or a two-stage system pre-alarm and main alarm. Options include a bar graph displaying smoke density levelsanda parallel display connection. Thanks to PIPE.GUARD HPLS light technology and LOGICSENS this air sampling smoke detection system is both highly sensitive and secure against false alarms.Key FeaturesThe primary alarm can be set to sensitivity levels as high as 0.1 obs.m.This air sampling smoke detectors 40 to 50m-long pipe system can have up to eight air sampling points 5 with ROOMIDENT.The TITANUSMICROSENShas a wide range of options so it can be customised to any number of situations.A second detector module can be incorporated to create a dual detector dependency configuration.Special versions are available for deep-freeze facilities temperatures as low as -40 C and noise-critical areas to 23 dB A.The plug-and-play system makes the air sampling smoke detector quick and easy to install.Maintenance work can be performed without entering the protected area.

GBP 1729.51
1

Wagner AD-05-4320 Detection Unit TITANUS MICROSENS - Bar Graph

Wagner AD-05-4320 Detection Unit TITANUS MICROSENS - Bar Graph

Wagner AD-05-4320 Detection Unit TITANUS MICROSENS - Bar GraphWagner AD-05-4320 Titanus MicroSens Detection Unit Bar Graph Version - DM-TM-B-50WAGNERs smallest air sampling smoke detector the TITANUSMICROSENS is designed for small to medium-sized areas up to 400 m in size. This economical air sampling smoke detector is ideal for use in hotel rooms offices and prison cells. The optional ROOMIDENT feature can localise fires within up to five rooms.The pint-sized TITANUSMICROSENSprovides a wealth of options. It can be configured to use a single primary alarm or a two-stage system pre-alarm and main alarm. Options include a bar graph displaying smoke density levelsanda parallel display connection. Thanks to PIPE.GUARD HPLS light technology and LOGICSENS this air sampling smoke detection system is both highly sensitive and secure against false alarms.Key FeaturesThe primary alarm can be set to sensitivity levels as high as 0.1 obs.m.This air sampling smoke detectors 40 to 50m-long pipe system can have up to eight air sampling points 5 with ROOMIDENT.The TITANUSMICROSENShas a wide range of options so it can be customised to any number of situations.A second detector module can be incorporated to create a dual detector dependency configuration.Special versions are available for deep-freeze facilities temperatures as low as -40 C and noise-critical areas to 23 dB A.The plug-and-play system makes the air sampling smoke detector quick and easy to install.Maintenance work can be performed without entering the protected area.

GBP 1114.49
1

Wagner AD-10-5210 Detector Module TT f. Pro Sensnet amp SILENT