403 results (0,15279 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Vimpex ACC0005 Agrippa Acoustic Door Closer with a Silver Finish

Vimpex VPSU-24-02-SN-A 24V dc 2A 1 x 2A PSU - No Battery Charging

Vimpex VPSU-24-01-SN-A 24V dc 1A 1 x 1A PSU - No Battery Charging

Vimpex VPSU-24-01-SN-A 24V dc 1A 1 x 1A PSU - No Battery Charging

Vimpex VPSU-24-01-SN-A 24V dc 1A 1 x 1A PSU - No Battery ChargingThe 24 V SN Range of power supplies consists of both low-profile and IP68 variants. The units are available in either 1 Amp 2 Amp and 4 Amp power ratings with options of up to 8 individually fused output circuits.Individual fused outputs can provide isolation of selected circuits when servicing or in the event one circuit fails allowing the rest of the system to operate normally maintaining system integrity.All units feature fuse health LEDs which are illuminated to show which powered circuit is functioning correctly. Each fused output circuit may have different value fuses to suit individual loads eg camera lighting etc...The 4 Amp Versions are offered in a lockable enclosure keyed alike while the 2 Amp versions possess a hinged screw lid. Cable entry is achieved by utilising either cable gland knockouts or via the allocated rear cable entry points of the enclosures.Key FeaturesIndividual fuse health LED indicationWhite powder coated 1.2 mm thick steel enclosureLockable lid 4 A variantsLow profile design 50 mm - internal modelsFully regulated 24 V dc outputHigh efficiency and cost-effective switch mode technologyFull rated current to loadElectronic short-circuit protectionInstaller safe shrouded high voltage electronicsReplaceable 20 mm mains and output fusesUniversal 90 - 264 V ac mains supplyMultiple cable entryexit optionsModular construction for easy servicing3-year warranty

GBP 72.20
1

Vimpex VPSU-24-04-SN-A 24V dc 4A 1 x 4A or 2 x 2A - No Battery Charging

Vimpex HS-WLDP Hydrosense HS Conventional Leak Detection Probe

Vimpex 10-2410RSX-S Identifire Surface Alarm System Red Connection Box

Vimpex VPSU-24-02A Boxed 24Vdc Power Supply 2A 235mm x 170mm x 87mm

Vimpex ELS3A6AO Loop Sounder with Deep Base IP66 in Red

Vimpex ELS3A6AO Loop Sounder with Deep Base IP66 in Red

Vimpex ELS3A6AO Loop Sounder with Deep Base IP66 in RedInstalling a Vimpex Loop Sounder System with short-circuit isolation provides complete sounder circuit integrity. By wiring the sounder circuit in a loop instead of a traditional radial all sounders will remain operational in the event of a short-circuit or open circuit fault.Component parts are approved by LPCB to relevant parts of EN 54 and the system is fully compliant with BS 5839-1 using a single sounder loop. Use of the Vimpex Loop Sounder System will greatly increase the reliability of the sounder circuits and in many cases result in a saving in the amount of cable used.Each loop can accommodate up to 45 sounders. Suitable for use on both conventional and addressable fire alarm systems the system provides much greater protection against faults than the dual radial circuit arrangements commonly used.The Vimpex Loop Sounder System significantly enhances the reliability of any sounder system. With conventional radial circuits a single open or short circuit fault on a sounder circuit could result in the loss of at least half of the sounders in an area of a building.The Vimpex Loop Sounder System has been fully tested and approved by LPCB to relevant EN 54 standards - certificates are available on request. This system is detailed in BS 5839-12002A22008 clause 12.2.2 j and Fig 1b as an alternative to the use of dual radial circuits. A detailed application guide is available from Vimpex as is a system loop calculator.Each sounder is supplied with a bi-directional short-circuit isolator fitted within its base. In the event of a short circuit the isolators will activate and disconnect the faulty section of cable while reporting in monitoring mode the fault to the control panel. When the sounders are activated the loop is driven from both ends ensuring that all sounders will remain operational even in the event of a single short-circuit or open-circuit fault. Sounders and their isolator bases are installed just like any other conventional sounders on the twin core circuit.

GBP 45.36
1

Vimpex ELS2A4AO Loop Sounder with Shallow Base in White

Vimpex ELS2A4AO Loop Sounder with Shallow Base in White

Vimpex ELS2A4AO Loop Sounder with Shallow Base in WhiteInstalling a Vimpex Loop Sounder System with short-circuit isolation provides complete sounder circuit integrity. By wiring the sounder circuit in a loop instead of a traditional radial all sounders will remain operational in the event of a short-circuit or open circuit fault.Component parts are approved by LPCB to relevant parts of EN 54 and the system is fully compliant with BS 5839-1 using a single sounder loop. Use of the Vimpex Loop Sounder System will greatly increase the reliability of the sounder circuits and in many cases result in a saving in the amount of cable used.Each loop can accommodate up to 45 sounders. Suitable for use on both conventional and addressable fire alarm systems the system provides much greater protection against faults than the dual radial circuit arrangements commonly used.The Vimpex Loop Sounder System significantly enhances the reliability of any sounder system. With conventional radial circuits a single open or short circuit fault on a sounder circuit could result in the loss of at least half of the sounders in an area of a building.The Vimpex Loop Sounder System has been fully tested and approved by LPCB to relevant EN 54 standards - certificates are available on request. This system is detailed in BS 5839-12002A22008 clause 12.2.2 j and Fig 1b as an alternative to the use of dual radial circuits. A detailed application guide is available from Vimpex as is a system loop calculator.Each sounder is supplied with a bi-directional short-circuit isolator fitted within its base. In the event of a short circuit the isolators will activate and disconnect the faulty section of cable while reporting in monitoring mode the fault to the control panel. When the sounders are activated the loop is driven from both ends ensuring that all sounders will remain operational even in the event of a single short-circuit or open-circuit fault. Sounders and their isolator bases are installed just like any other conventional sounders on the twin core circuit.

GBP 44.11
1

Vimpex Loop Sounder with Short Circuit Isolator ELS2A6AO

Vimpex Loop Sounder with Short Circuit Isolator ELS2A6AO

Vimpex Loop Sounder with Short Circuit Isolator ELS2A6A0Installing a Vimpex Loop Sounder System with short-circuit isolation provides complete sounder circuit integrity. By wiring the sounder circuit in a loop instead of a traditional radial all sounders will remain operational in the event of a short-circuit or open circuit fault.Component parts are approved by LPCB to relevant parts of EN 54 and the system is fully compliant with BS 5839-1 using a single sounder loop. Use of the Vimpex Loop Sounder System will greatly increase the reliability of the sounder circuits and in many cases result in a saving in the amount of cable used.Each loop can accommodate up to 45 sounders. Suitable for use on both conventional and addressable fire alarm systems the system provides much greater protection against faults than the dual radial circuit arrangements commonly used.The Vimpex Loop Sounder System significantly enhances the reliability of any sounder system. With conventional radial circuits a single open or short circuit fault on a sounder circuit could result in the loss of at least half of the sounders in an area of a building.Each sounder is supplied with a bi-directional short-circuit isolator fitted within its base. In the event of a short circuit the isolators will activate and disconnect the faulty section of cable while reporting in monitoring mode the fault to the control panel. When the sounders are activated the loop is driven from both ends ensuring that all sounders will remain operational even in the event of a single short-circuit or open-circuit fault. Sounders and their isolator bases are installed just like any other conventional sounders on the twin core circuit.Key FeaturesApproved to EN 54

GBP 44.11
1

Vimpex Fire-Cryer FC3ARRS Wall Mounted Red Beacon Shallow Base

Vimpex CBE6-230-MP-EN Mains Pack Accessory For ClamBell

Vimpex ID-WLMRC Hydrosense ID Addressable Mains Relay Controller

Vimpex IDAP-S-R-24 Hydrosense ID Addressable Leak Detection Repeater Panel 24VDC

Vimpex IDAP-S-R-230 Hydrosense ID Addressable Leak Detection Repeater Panel 230VAC

Vimpex SL-HDP-LHC-N Signaline HD -R Programmable Linear Heat Cable Nylon Coated - 50m

Vimpex SL-HDP-LHC Signaline HD Programmable Linear Heat Cable - 50m

Vimpex IC38230 IdentiCryer 8 Zone Conventional Panel

Vimpex IC34230 IdentiCryer 4 Zone Conventional Panel

Vimpex IC32230 IdentiCryer 2 Zone Conventional Panel

Vimpex Fire-Cryer FC3ARRD Wall Mounted Red Beacon Deep Base IP66

Vimpex SL-FT-105-CT Signaline ULFM 105C Red PVC amp Catenary LHD Cable - 50 Metres

Vimpex SL-HDP-LHC-S Signaline HD -S Programmable Linear Heat Cable Stainless Steel Braid - 50m