227 results (0,14688 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Notifier Interface IO BS7273-4 Door Release System NFX-DRS-1

Notifier Honeywell Multimode Fibre Optic Plug-in Module 583392.11

Notifier Round 5 inch Ceiling Loudspeaker LSC-506

Notifier NFXI-OSI-RIE Addressable OSID-R Beam Detector - 5-100M Range

Notifier PRL-LED-EN-1 Pearl Fixed 1 Loop Intelligent Fire Alarm Control Panel with 64 LEDs

Notifier PRL-LED-EN-1 Pearl Fixed 1 Loop Intelligent Fire Alarm Control Panel with 64 LEDs

Notifier PRL-LED-EN-1 Pearl Fixed 1 Loop Intelligent Fire Alarm Control Panel with 64 LEDsThe Pearl fire alarm control panel from Notifier by Honeywell is a robust and easy to use networkable 1 or 2 loop panel. It exploits Notifiers class leading Opal digital protocol to maximise the speed and efficiency of fire detection and alarm. The large display with its intuitive interface and menu driven features allows quick and easy operation of the system.Coupled with more power and devices on the loop than other panels in its class the simple design will allow for trouble-free first fix installation. Compatible with the ID2net network used by the ID3000 the Pearl panel is supported by an integrated tools suite to enhance and simplify the system management.Extended capacityThe Pearl supports up to 636 loop devices 159 detectors plus 159 modules per loopLonger loops but fewer of them will give the opportunity to save on installation time cost and wiringHighly resilient Opal system able to pinpoint a loop fault whilst maintaining full system operationPowerful networking capability - Up to 16 Pearl panels controlling over 10000 devices can be networked via the superfast ID2net prioritising a fire signal to communicate across a network in under three secondsEase of useIntuitive on-site management - backlit buttons for fast error free situation management and large display giving complete information at a glanceSimpler diagnostics and maintenance - panel control of detector LEDs enabling confirmation of detector statusText programming via MS Excel spread sheetUser permissions set per individual passwordFlexibilityUnique first fix bracket with adaptations for 19 rack or flush mounting.Fast system set up and commissioning via the panel loop Autolearn and advanced PC tools suiteComprehensive Cause Effect programming capabilityPanel sounder and beacon synchronisationSystem extensions and adaptations can be made quickly without compromising fire cover and without extensive re-cablingSeparate text change without risk to Cause Effect or system configuration.Ability to run BS5839 part 6 system for HMO

GBP 1619.16
1

Notifier HOP-402-100 Charger Module 1 Supplied

Notifier ABT-TNL100-1 Tunnel Horn Loudspeaker - 100 W with 76 horizontal x 90 Vertical Display

Notifier ABT-TNL100-1 Tunnel Horn Loudspeaker - 100 W with 76 horizontal x 90 Vertical Display

Notifier ABT-TNL100-1 Tunnel Horn Loudspeaker - 100 W with 76 horizontal x 90 Vertical DisplayIn case of an emergency the Voice Evacuation System needs to guide people in the tunnel to safety so the audio transmission should be as clear as possible. In general due to high levels of reverberation and noise a tunnel is not an ideal environment for Voice Evacuation System and therefore speech intelligibility becomes a critical parameter for any voice alarm application. To establish a sufficient level of speech intelligibility a highly directional speakers system is required. By reducing the energy emitted to other surfaces reflective sound energy can be minimized which results in a better direct to reverberant ratio. This will improve the maximum feasible speech intelligibility. To minimize disturbing echo effects resulting in a loss of speech intelligibility each horn speaker is driven by an individual signal channel in a 100 V installation which is equipped with audio DSP including EQ and delay. Our product S4T Safety For Tunnel offers the most effective solution which seamlessly combines a dedicated Voice Evacuation System with tailored Tunnel Loudspeakers.Key FeaturesSpecially designed for tunnel applicationsHighly directional asymmetric hornExcellent speech intelligibilityStainless steel constructionWaterproof housing IP66High power output 10050 WCompliance with BS5839-8 standard Thermal protection

GBP 4521.70
1

Notifier Honeywell 583392.11 Fibre Optic Module For FO Switch Multimode

Notifier Honeywell 583393.11 Fibre Optic Module for FO Switch Single Mode

Notifier Honeywell ABT-ISLE Audio RS485 Interface

Notifier Honeywell VCM View Control Module 583351

Notifier Local Silence Button Kit NF-SIL-BKIT

Notifier Local Silence Button Kit NF-SIL-BKIT

Notifier Local Silence Button Kit NF-SIL-BKITThe NOTIFIER Local Silence Button in conjunction with the advanced programmingprovided by the Pearl control panel enables the use of a full BS5839 Part 1 system inapplications such as assisted living retirement homes student accommodation highrise residential buildings. Often the risk of false alarm in such buildings has led to thesesorts of installation being provided with individual systems for the flats linked to alandlord system for the shared area.The use of the NOTIFIER local silence button and Type-B dependency programmingnow enables full BS 5839 Part 1 systems to be installed in all areas.Type B DependencyType B dependency allows a zone to be defined for each individual flat that acts as ifit were a separate system. On receipt of an unconfirmed fire signal from a flat onlythe local alarm within the flat is given. If the alarm is confirmed by a second signal thesystem proceeds to the relevant evacuation stage general alarm or part of stagedevacuation. Alternatively if the confirmation signal is not given the system may resetautomatically without attendance by facility management staff.Local Silence ButtonThe local silence button is a multi-position switch that allows not only sounder test andsilencing but also disablement of smoke detection and the indication of disablement. Aswith other features it is flexible in configuration so that the facilities may be tailored tosuit each site.NOTIFIER NF-SIL-BKIT LOCAL SILENCE BUTTON KIT FEATURESBest detection throughout. AllowsOpal multi criteria detectors to reducefalse alarms.Fully configurable. Allowing theinstaller to design delay periods andresponse times on all parts of thesystem in order to ensure it meetsyour building requirements.Flexible and simple to install. TheLocal Silence Button is available in a kitincluding wiring loom and loop moduleSupporting compliance. BS5839 Part6 requires the alarm in each dwellingto be tested on a regular basis. Thisactivity is logged on the Pearl systemallowing landlords to check theresidents are performing this taskensuring fire safety and compliance.Local Silence of an AlarmThe user is able to silence the local sounder or sounder beacons within their premisesby pressing the Fire Alarm Silence button when a detector has activated within theirpremises. When the site is in a full evacuation mode this feature is disabled and thelocal sounder or sounder beacons cannot be silenced by the user.Local DisablementIf the user believes that they may generate an unwanted alarm from a smoke detectorwithin their premises they can press and hold the Fire Alarm Silence button for 5seconds. The yellow LED illuminates which will then disable the detection in that zoneonly for a configurable period of between 5-15 minutes in accordance with BS5839 Part 6.At the end of the configured period the zone will automatically re-enable all detectionwill be active and the LED will be extinguished.Local TestA test feature is available which allows the user to operate the sounder or sounderbeacons within the local zone by pressing and holding down the Fire Alarm Testbutton once released the sounder or sounder beacons will silence.ConnectionThe button is connected to the Pearl loop via a Notifier 21 dual input single outputinterface unit and a 5-core cable.

GBP 287.16
1

Notifier Honeywell 30 Watt Horn Loudspeaker 582432

Notifier Honeywell ABT-DMS Zone Microphone