174 results (0,14572 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Kidde AD68P-0500 Alarmline 68 Degree Alarm Temperature Digital Sensor Cable PVC and Poly

Kidde AD68P-0100 Alarmline 68 Degree Alarm Temperature Digital Sensor Cable PVC and Poly

Kidde AD68N-1000 Alarmline 68 Degree Alarm Temperature Digital Sensor Cable Nylon

Kidde AD68N-0500 Alarmline 68 Degree Alarm Temperature Digital Sensor Cable Nylon

Kidde Alarmline AD68SS-0100 68 Degree Alarm Temperature Digital Sensor Cable PVC and Stainless Steel

Kidde AD68N-0100 Alarmline 68 Degree Alarm Temperature Digital Sensor Cable Nylon

Kidde Alarmline AD68SS-0500 68 Degree Alarm Temperature Digital Sensor Cable PVC and Stainless Steel

Kidde AirSense Stratos Command Module in Steel Enclosure 9-30709

Kidde AirSense Stratos HSSD 2 Detector in Steel Enclosure 9-30706

Kidde AirSense Stratos HSSD 2 Detector in Steel Enclosure 9-30706

Kidde AirSense Stratos HSSD 2 Detector in Steel Enclosure 9-30706Stratos HSSD2 is designed to provide very high sensitivity smoke detection ensuring the very earliest warning of incipient fire with minimum rate of nuisance alarms. ClassiFire Perceptive Artificial Intelligence ensures that the detector operates at optimum sensitivity for the protected environment without the need for complex setup.This means the product will configure itself to provide high sensitivity in a computer room or reduced sensitivity in a smoky area. Upgradable volt-free Fire and Fault relay outputs are available for remote monitoring by local fire detection or BMS systems. Command module available for central monitoring and display.Typical ApplicationsData storage unitsPrison cellsPlant roomsAir conditioning unitsEquipment racksComputer roomsAir duct protectionHeritage property protectionCritical equipmentAnti-smoking enforcementMotor roomsKey FeaturesHigh sensitivity provided by laser based forward light scatter for reliable early warningCombined sampling pipe up to 200m in length still airUnique ClassiFire Perceptive Artificial Intelligence system that dynamically adjusts the detectors operating parameters allowing for day to day changes in the protected environment and dust separation system contaminationUnwanted alarms from dust are avoided using patented Dual Technology LDD 3D3 Laser Dust Discrimination and elimination systemRS485 communications built in as standard for networking and remote communicationsLarge area aspirating smoke detector up to 2000m2 coverageCPR LPCB VdS NF CSIRO UL FM approved

GBP 2231.89
1

Kidde AirSense Stratos HSSD 2 Detector with Command Module in Steel Enclosure 9-30707

Kidde AirSense Stratos HSSD 2 Detector with Command Module in Steel Enclosure 9-30707

Kidde AirSense Stratos HSSD 2 Detector with Command Module in Steel Enclosure 9-30707Stratos HSSD2 is designed to provide very high sensitivity smoke detection ensuring the very earliest warning of incipient fire with minimum rate of nuisance alarms. ClassiFire Perceptive Artificial Intelligence ensures that the detector operates at optimum sensitivity for the protected environment without the need for complex setup.This means the product will configure itself to provide high sensitivity in a computer room or reduced sensitivity in a smoky area. Upgradable volt-free Fire and Fault relay outputs are available for remote monitoring by local fire detection or BMS systems. Command module available for central monitoring and display.Typical ApplicationsData storage unitsPrison cellsPlant roomsAir conditioning unitsEquipment racksComputer roomsAir duct protectionHeritage property protectionCritical equipmentAnti-smoking enforcementMotor roomsKey FeaturesHigh sensitivity provided by laser based forward light scatter for reliable early warningCombined sampling pipe up to 200m in length still airUnique ClassiFire Perceptive Artificial Intelligence system that dynamically adjusts the detectors operating parameters allowing for day to day changes in the protected environment and dust separation system contaminationUnwanted alarms from dust are avoided using patented Dual Technology LDD 3D3 Laser Dust Discrimination and elimination systemRS485 communications built in as standard for networking and remote communicationsLarge area aspirating smoke detector up to 2000m2 coverageCPR LPCB VdS NF CSIRO UL FM approved

GBP 3320.40
1

Kidde Airsense EST-xCtrLine-2 Function Card 8 IN Audio

Kidde Airsense EST-XAUDIO-48-RS Function Card 4 IN 8 OUT Audio RS485

Kidde Airsense EST-XCTRLINE-4 Function Card 4 IN 8 OUT Audio RS485

Kidde Airsense ADELCU-2 Alarmline II Digital LHD EN54-28 Dual Zone Location Control Unit

Kidde Airsense ADELCU-2 Alarmline II Digital LHD EN54-28 Dual Zone Location Control Unit

Kidde Airsense ADELCU-2 Alarmline II Digital LHD EN54-28 Dual Zone Location Control UnitThe ADELCU-2 digital location control unit is a dual zone module for monitoring up to two zones of AlarmLine II Digital EN Linear Heat Detection Cable. If an overheat or fire situation triggers either zone of the digital cable the unit automatically calculates and displays the distance along the cable in feet and metres to the alarm point.The two zones can operate independently of each other or in interlock mode. A separate alarm and normally conducting fault output are provided for each zone. The unit is intended to be installed between the AlarmLine II digital EN linear heat detection cable and a conventional or addressable fire alarm control panel. It has power fault and alarm indicators as well as free outputs for fault and alarm corresponding to each zone. It may also be connected to a industrial process control system using the two wire RS-485 Modbus RTU output.Modbus communicationThe unit includes a two wire RS-485 Modbus output which can be enabled to output the status of each zone of the digital location control unit via Modbus RTUASCII protocol. In case of an alarm the location in distance along the cable is also communicated via Modbus.Interconnecting cableThe unit supports the use of a interconnecting cable leader cable in between the control unit and the linear heat detection cable. The interconnecting cable is used in applications where the control unit is not located in the detection zone. The interconnecting cable is then used to connect the control unit in one location with the linear heat detection cable in the protected area. The interconnecting cable is available in 100 m lengths under the product code AAI-0100.Key FeaturesDual Zone - used as Independent or InterlockDesigned for AlarmLine II Digital EN linear heat cableEasy to installIP Rating IP65RoHS compliant CE EN54-282016 certifiedModbus support1km of cable supported per zoneWide supply voltageLow current consumption

GBP 1253.77
1

Kidde Airsense EST-XLOGIN-8F 8 Logical Inputs Card Function Slot

Kidde Airsense EST-XLOGIN-8C 8 Logical Inputs Card Control Slot

Kidde 1X-X3E-99 Conventional Fire amp Extinguishing Panel With UI - 3 Zone - Full Opt Eng Int

Kidde 1X-X3E-99 Conventional Fire amp Extinguishing Panel With UI - 3 Zone - Full Opt Eng Int

Kidde 1X-X3E-99 Conventional Fire Extinguishing Panel With UI - 3 Zone - Full Opt Eng IntThe 1X-X3E-99 is a networkable enhanced conventional fire alarm and extinguishing control panel. It is supplied in local language with 3 fire zones that support up to 32 devices per zone. These zones may be configured for extinguishing in single zone or double zone configuration in any combination of zones. In addition the panel offers supervised outputs for first stage notification second stage notification as well as optical warning indicators and actuator activation. Standard relay outputs are provided for EN54 compliance and system status notification as well as multiple inputs for system control.The 1X fire control panels offer state of the art architecture in configurations that deliver an uncomplicated solution for small to mid-sized conventional applications. They feature an attractive contemporary design that fits with any dcor. The gently curved door front offers a distinctive flair. Operator controls are inset in a striking black lexan.With support for multiple lines of conventional detectors and accessories these quick-to-configure systems offer versatility that benefits building owners and installationmaintenance companies alike.OptionsThe panels support 2 types of auxiliary relay boards one with 4 standard relays and one with 4 supervised relays. With these boards the panel outputs may be expanded with up to 16 additional outputs. The 1X-X3E supports class A redundant ring and B standard bus networking with up to 32 nodes including conventional and addressable panels and repeaters via an optional network interface. This allows full remote control and inputs to and from other nodes in the system providing superior flexibility in system organization and planning.Key FeaturesSounders configurable for pulsing or continuous operationExtinguishing agent flow confirmationContinuous or resettable 24 VDC auxiliary supplyAuxiliary standard supervised relay output supportIntrinsically safe and EN54-13 zone support

GBP 412.79
1

Kidde Airsense APIC Card Apollo Protocol 9-30430