368 results (0,15733 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Kentec K1822-00 Sigma A-XT Ancillary PCB

Kentec K1822-40 Boxed Sigma A-XT Ancillary PCB Grey

Kentec K1822-10 Boxed Sigma A-XT Ancillary PCB Red

Kentec K1885-48 Sigma A-CP Conventional Annunciator Panel Grey

Kentec K1885-18 Sigma A-CP Conventional Annunciator Panel Red

Kentec DNX-A-2R-K RS485 Dynamic Network Analyser

Kentec DNX-A-2R-K RS485 Dynamic Network Analyser

Kentec DNX-A-2R-K RS485 Dynamic Network AnalyserThe DNX-A-2R-K is an RS485 Dynamic Network Analyser for Ring Topology Networks. This product has been developed to facilitate dynamic network management through the provision of an independent communication layer.The equipment is designed to improve the Quality of Service QoS of critical communication networks while operating under the performance criteria required by EN54-13 and BS5839 part 1.The ports connected to the communications ring are correctly terminated to match the network communications cable impedance to ensure optimum signal quality and amplitude.Signal quality is constantly monitored and the termination impedance is adjusted to compensate for changes in cable impedance due to climatic or physical cable parameter changes.Four InputOutput interfaces are provided for through an independent communications layer. This feature provides a basic redundant network protocol with the mapping configuration managed through the PC graphics IVIEW programming tool.An upgrade license DNX-R-2R-K-UG is available for this module which enables compatibility with IVIEW graphical software for network analysis support.Key FeaturesIndependent reporting with Class A communication redundancy with multiple fault tolerance2.5 kV galvanic isolation on all portsDual and single industrial equipment RS485 connection4 independent IO channels across the redundant network ring for independent protocol redundancyCan operate on Hosted Fibre Ethernet linksSimple LED system status indicationSignal quality and amplitude visual indicationWireless connectivity for remote monitoring using a Bluetooth or WiFi interfaceSupports the generation of system performance reports for Installation commissioningVisual interface provide by IVIEW the graphical user interface with monitoring diagnostics and reporting optionsEnables preventative maintenance management through system degradation monitoringConfiguration and commissioning parameters are stored allowing for system performance tracking over timeBaud rate selectable from 9600-115200 bitssecDIN rail mounting

GBP 1591.74
1

Kentec K1842-40 Sigma A-CP 2 Zone Control Panel 115V - Grey

Kentec K1842-41 Sigma A-CP 2 Zone Control Panel 240V - Grey

Kentec K1842-10 Sigma A-CP 2 Zone Control Panel 115V - Red

Kentec KA11040M2 Sigma CP-A Alarmsense Conventional Panel 4 Zones

Kentec KA11040M2 Sigma CP-A Alarmsense Conventional Panel 4 Zones

Kentec KA11040M2 Sigma CP-A Alarmsense Conventional Panel 4 Zones The Sigma CP-A AlarmSense range consists of a series of conventional two four and eight zone fire alarm control panels. The AlarmSense system enables all detection and sounder devices in a given zone to be wired to the same pair of cables greatly reducing the cabling and installation requirements and hence costs.The AlarmSense range of devices includes smoke and heat detectors call points base sounders base sounderbeacons and relay units all wired to the same pair of cables. Having sounders and sounder beacons installed on the same cabling as detectors and call points allows all systems to be configured for common zonal or two-stage alarms by simply setting one of the panels configuration options.Selection of the AlarmSense local alarm feature at sounder or sounder beacon bases invokes the alarm verification feature. This is particularly useful in Houses of Multiple Occupation such as student accommodation or nursing homes. When sounder or sounder beacon bases are selected for local alarm mode alarms are restricted such that only the sounder connected to the activated detector will operate initially.The panel will attempt to reset the activated detector after a time delay and if successful no further alarms are sounded. If the detector re-activates after being reset a general alarm will sound throughout the premises. The alarm verification feature of the Sigma CP-A control panel greatly reduces the risk of unwanted alarms or call outs while still providing secure high quality fire protection throughout the premises.Key Features 2 wire systems reduces installation cabling 2-wire repeaters and ancillary boards via serial bus Fully programmable using simple menu options Adjustable sounder delay time Sounder configuration options Zonal sounder delay for detectors only Zonal sounder delay for call points only Coincidence output via ancillary board Short circuit fire selectable by zone Non latching selection by zone Silent zones common sounder outputs Zone input delay for sprinkler system connection AlarmSense local alarm feature supported Simple single board construction Installer friendly Compatible with all AlarmSense devices Two conventional monitored sounder outputs 3 Amp power supply Auxiliary power output Fully certified to BS EN54-2 and BS EN54-4 Allows systems to be installed in accordance with BS5839 Part 6

GBP 335.34
1

Kentec KA11080M2 Sigma CP-A Alarmsense Conventional Panel 8 Zones

Kentec KA11080M2 Sigma CP-A Alarmsense Conventional Panel 8 Zones

Kentec KA11080M2 Sigma CP-A Alarmsense Conventional Panel 8 ZonesThe Sigma CP-A AlarmSense range consists of a series of conventional two four and eight zone fire alarm control panels. The AlarmSense system enables all detection and sounder devices in a given zone to be wired to the same pair of cables greatly reducing the cabling and installation requirements and hence costs.The AlarmSense range of devices includes smoke and heat detectors call points base sounders base sounderbeacons and relay units all wired to the same pair of cables. Having sounders and sounder beacons installed on the same cabling as detectors and call points allows all systems to be configured for common zonal or two-stage alarms by simply setting one of the panels configuration options.Selection of the AlarmSense local alarm feature at sounder or sounder beacon bases invokes the alarm verification feature. This is particularly useful in Houses of Multiple Occupation such as student accommodation or nursing homes. When sounder or sounder beacon bases are selected for local alarm mode alarms are restricted such that only the sounder connected to the activated detector will operate initially.The panel will attempt to reset the activated detector after a time delay and if successful no further alarms are sounded. If the detector re-activates after being reset a general alarm will sound throughout the premises. The alarm verification feature of the Sigma CP-A control panel greatly reduces the risk of unwanted alarms or call outs while still providing secure high quality fire protection throughout the premises.Key Features 2 wire systems reduces installation cabling 2-wire repeaters and ancillary boards via serial bus Fully programmable using simple menu options Adjustable sounder delay time Sounder configuration options Zonal sounder delay for detectors only Zonal sounder delay for call points only Coincidence output via ancillary board Short circuit fire selectable by zone Non latching selection by zone Silent zones common sounder outputs Zone input delay for sprinkler system connection AlarmSense local alarm feature supported Simple single board construction Installer friendly Compatible with all AlarmSense devices Two conventional monitored sounder outputs 3 Amp power supply Auxiliary power output Fully certified to BS EN54-2 and BS EN54-4 Allows systems to be installed in accordance with BS5839 Part 6

GBP 386.92
1

Kentec K1810-43 Sigma A-XT Extinguishant Control Panel - 230V Grey

Kentec K1810-43 Sigma A-XT Extinguishant Control Panel - 230V Grey

Kentec K1810-43 Sigma A-XT Extinguishant Control Panel - 230V GreySigma A-XT releasing panel offers outstanding value and performance for all small to medium fixed fire-fighting installations.With three initiating circuits as standard release can be configured to activate from any combination of detection zone inputs to allow among other combinations any two from three types of activations for detection in ceiling void room and floor void applications.The extensive configuration options of the Sigma A-XT allow the functionality of the system to be extensively modified. The panel contains a large LED display to enable easy configuration and control which also displays the time remaining until release for added user safety.The countdown time is duplicated on up to seven remote status units to provide local indication of the system status.With all the electronics mounted on a single easily removable steel plate Sigma A-XT panels are both robust and easy to install. Sigma A-XT is supplied in an enclosure that matches the design and colour of the Elite RS range and is available in standard red or optional grey.The K16400M2 from the extensive range of Kentec products is a syncro IO expansion card enclosure with 5.25A power supply. flexibility to create customised IO panel.Key FeaturesUL864 and FM ListedThree initiation circuits as standardAny single zone or any combinations of zones can be configured to releaseConfigurable first stage NAC delaysConfigurable detection delaysZero time delay upon manual release optionSupports up to seven four wire status indicatorsBuilt in Extract Fan controlCompatible with I.S. barriersNon-latching zone input option to receive signals from other systems such as aspirating equipmentConfigurable releasing delays up to 60 seconds in 5 second stopsConfigurable releasing duration up to 5 minutes in 5 second stepsCountdown timer shows time remaining until release

GBP 628.31
1

Kentec K1810-44 Sigma A-XT Extinguishant Control Panel - 115V Grey

Kentec K1810-44 Sigma A-XT Extinguishant Control Panel - 115V Grey

Kentec K1810-44 Sigma A-XT Extinguishant Control Panel - 115V GreySigma A-XT releasing panel offers outstanding value and performance for all small to medium fixed fire-fighting installations.With three initiating circuits as standard release can be configured to activate from any combination of detection zone inputs to allow among other combinations any two from three types of activations for detection in ceiling void room and floor void applications.The extensive configuration options of the Sigma A-XT allow the functionality of the system to be extensively modified. The panel contains a large LED display to enable easy configuration and control which also displays the time remaining until release for added user safety.The countdown time is duplicated on up to seven remote status units to provide local indication of the system status.With all the electronics mounted on a single easily removable steel plate Sigma A-XT panels are both robust and easy to install. Sigma A-XT is supplied in an enclosure that matches the design and colour of the Elite RS range and is available in standard red or optional grey.The K16400M2 from the extensive range of Kentec products is a syncro IO expansion card enclosure with 5.25A power supply. flexibility to create customised IO panel.Key FeaturesUL864 and FM ListedThree initiation circuits as standardAny single zone or any combinations of zones can be configured to releaseConfigurable first stage NAC delaysConfigurable detection delaysZero time delay upon manual release optionSupports up to seven four wire status indicatorsBuilt in Extract Fan controlCompatible with I.S. barriersNon-latching zone input option to receive signals from other systems such as aspirating equipmentConfigurable releasing delays up to 60 seconds in 5 second stopsConfigurable releasing duration up to 5 minutes in 5 second stepsCountdown timer shows time remaining until release

GBP 628.31
1

Kentec K1810-13 Sigma A-XT Extinguishant Control Panel - 230V Red

Kentec K1810-13 Sigma A-XT Extinguishant Control Panel - 230V Red

Kentec K1810-13 Sigma A-XT Extinguishant Control Panel - 230V RedSigma A-XT releasing panel offers outstanding value and performance for all small to medium fixed fire-fighting installations.With three initiating circuits as standard release can be configured to activate from any combination of detection zone inputs to allow among other combinations any two from three types of activations for detection in ceiling void room and floor void applications.The extensive configuration options of the Sigma A-XT allow the functionality of the system to be extensively modified. The panel contains a large LED display to enable easy configuration and control which also displays the time remaining until release for added user safety.The countdown time is duplicated on up to seven remote status units to provide local indication of the system status.With all the electronics mounted on a single easily removable steel plate Sigma A-XT panels are both robust and easy to install. Sigma A-XT is supplied in an enclosure that matches the design and colour of the Elite RS range and is available in standard red or optional grey.The K16400M2 from the extensive range of Kentec products is a syncro IO expansion card enclosure with 5.25A power supply. flexibility to create customised IO panel.Key FeaturesUL864 and FM ListedThree initiation circuits as standardAny single zone or any combinations of zones can be configured to releaseConfigurable first stage NAC delaysConfigurable detection delaysZero time delay upon manual release optionSupports up to seven four wire status indicatorsBuilt in Extract Fan controlCompatible with I.S. barriersNon-latching zone input option to receive signals from other systems such as aspirating equipmentConfigurable releasing delays up to 60 seconds in 5 second stopsConfigurable releasing duration up to 5 minutes in 5 second stepsCountdown timer shows time remaining until release

GBP 628.31
1

Kentec K1810-12 Sigma A-XT Extinguishant Control Panel 115V Red

Kentec K1810-12 Sigma A-XT Extinguishant Control Panel 115V Red

Kentec K1810-12 Sigma A-XT Extinguishant Control Panel 115V RedSigma A-XT releasing panel offers outstanding value and performance for all small to medium fixed fire-fighting installations.With three initiating circuits as standard release can be configured to activate from any combination of detection zone inputs to allow among other combinations any two from three types of activations for detection in ceiling void room and floor void applications.The extensive configuration options of the Sigma A-XT allow the functionality of the system to be extensively modified. The panel contains a large LED display to enable easy configuration and control which also displays the time remaining until release for added user safety.The countdown time is duplicated on up to seven remote status units to provide local indication of the system status.With all the electronics mounted on a single easily removable steel plate Sigma A-XT panels are both robust and easy to install. Sigma A-XT is supplied in an enclosure that matches the design and colour of the Elite RS range and is available in standard red or optional grey.The K16400M2 from the extensive range of Kentec products is a syncro IO expansion card enclosure with 5.25A power supply. flexibility to create customised IO panel.Key FeaturesUL864 and FM ListedThree initiation circuits as standardAny single zone or any combinations of zones can be configured to releaseConfigurable first stage NAC delaysConfigurable detection delaysZero time delay upon manual release optionSupports up to seven four wire status indicatorsBuilt in Extract Fan controlCompatible with I.S. barriersNon-latching zone input option to receive signals from other systems such as aspirating equipmentConfigurable releasing delays up to 60 seconds in 5 second stopsConfigurable releasing duration up to 5 minutes in 5 second stepsCountdown timer shows time remaining until release

GBP 628.31
1

Kentec Sigma A-CP Conventional Control Panel ULFM Approved K1842-11

Kentec Sigma A-CP Conventional Control Panel ULFM Approved K1842-11

Kentec Sigma A-CP Conventional Control Panel ULFM ApprovedThe Sigma A-CP range of conventional fire control panels with optional built in communicator are available with 2 4 or 8 initiating circuits which may be extensively configured via a simple front panel operated programming method. The low standby power requirements and cost effective small batteries allow the panel to be mounted in a small discrete enclosure which is available in standard red or optionally in an attractive grey colour.A simple programming method using just 3 front panel buttons allows an extensive list of configuration options to be set and reviewed. Single board construction which allows easy removal of all electronic parts by removing just 2 screws and ample provision of cable entry knockouts simplify installation. 4 Amp notification appliances power and built in selectable sync protocols provide ample power and control for a wide range of standard notification appliances.The built in RS485 communications bus provides the facility to connect 4 wire annunciators or ancillary relay boards to provide further indication and control options throughout a premises. The optional DACT allows dual line reporting to central stations and provides a 500 event history buffer.Key FeaturesUL864 approvedTwo four or eight initiating circuitsInitiating circuits individually configurable asFire Water flow or SupervisoryTwo 2A notification appliance circuitsSelectable NAC sync protocolsTwo 2.0A notification appliance circuits6.5A power supplyAlarm verification selectable by zoneResettable Aux power output rated at 0.3AAux power configurable to power off onFire conditionFire Trouble and Supervisory relaysSingle person walk test functionOptional DACTMany advanced configuration options72 hour standby with 7Ah batteriesCompact enclosureFire Drill capability

GBP 377.57
1

Kentec K1844-11 Sigma A-CP 4 Zone Control Panel 240V Red

Kentec K1844-11 Sigma A-CP 4 Zone Control Panel 240V Red

Kentec K1844-11 Sigma A-CP 4 Zone Control Panel 240V RedThe Sigma A-CP is a range of conventional fire control panelswith an optional built-in communicator. With two four or eight initiatingcircuits all panels can be extensively configured via a simple front paneloperated programming method. The low standby power requirements and costeffective small batteries allow the panel to be mounted in a discrete enclosurewhich is available in red or grey. A simple programming method using just 3front panel buttons allows an extensive list of configuration options to be setand reviewed. Single board construction enables easy removal of all electronicparts by removing just two screws and ample provision of cable entry knockoutssimplify installation. 4 Amp notification appliance power and built-inselectable sync protocols provide ample power and control for a wide range ofstandard notification appliances. The built-in RS485 communications busprovides the facility to connect 4 wire annunciators or ancillary relay boardsto provide further indication and control options throughout a premises. Theoptional DACT allows dual line reporting to central stations and provides a500-event history buffer.Key Features4 Zone CircuitsInitiating circuits individually configurable as Fire Water Flow or SupervisoryTwo 2A notification appliance circuitsSelectable NAC sync protocols6.5A power supplyAlarm verification selectable by zoneResettable aux power output rated at 0.3AAux power configurable to power off on Fire conditionFire trouble and supervisory relaysSingle person walk test functionOptional DACTAdvanced configuration options72 hour standby with 7Ah batteriesCompact enclosureUL864 listed

GBP 431.34
1

Kentec K1844-10 Sigma A-CP 4 Zone Control Panel 115V Red

Kentec K1844-10 Sigma A-CP 4 Zone Control Panel 115V Red

Kentec K1844-10 Sigma A-CP 4 Zone Control Panel 115V RedThe Sigma A-CP is a range of conventional fire control panelswith an optional built-in communicator. With two four or eight initiatingcircuits all panels can be extensively configured via a simple front paneloperated programming method. The low standby power requirements and costeffective small batteries allow the panel to be mounted in a discrete enclosurewhich is available in red or grey. A simple programming method using just 3front panel buttons allows an extensive list of configuration options to be setand reviewed. Single board construction enables easy removal of all electronicparts by removing just two screws and ample provision of cable entry knockoutssimplify installation. 4 Amp notification appliance power and built-inselectable sync protocols provide ample power and control for a wide range ofstandard notification appliances. The built-in RS485 communications busprovides the facility to connect 4 wire annunciators or ancillary relay boardsto provide further indication and control options throughout a premises. Theoptional DACT allows dual line reporting to central stations and provides a500-event history buffer.Key Features4 Zone CircuitsInitiating circuits individually configurable as Fire Water Flow or SupervisoryTwo 2A notification appliance circuitsSelectable NAC sync protocols6.5A power supplyAlarm verification selectable by zoneResettable aux power output rated at 0.3AAux power configurable to power off on Fire conditionFire trouble and supervisory relaysSingle person walk test functionOptional DACTAdvanced configuration options72 hour standby with 7Ah batteriesCompact enclosureUL864 listed

GBP 431.34
1

Kentec K1848-41 Sigma A-CP 8 Zone Control Panel 240V Grey

Kentec K1848-41 Sigma A-CP 8 Zone Control Panel 240V Grey

Kentec K1848-41 Sigma A-CP 8 Zone Control Panel 240V GreyThe Sigma A-CP is a range of conventional fire control panelswith an optional built-in communicator. With two four or eight initiatingcircuits all panels can be extensively configured via a simple front paneloperated programming method. The low standby power requirements and costeffective small batteries allow the panel to be mounted in a discrete enclosurewhich is available in red or grey. A simple programming method using just 3front panel buttons allows an extensive list of configuration options to be setand reviewed. Single board construction enables easy removal of all electronicparts by removing just two screws and ample provision of cable entry knockoutssimplify installation. 4 Amp notification appliance power and built-inselectable sync protocols provide ample power and control for a wide range ofstandard notification appliances. The built-in RS485 communications busprovides the facility to connect 4 wire annunciators or ancillary relay boardsto provide further indication and control options throughout a premises. Theoptional DACT allows dual line reporting to central stations and provides a500-event history buffer.Key Features8 Zone CircuitsInitiating circuits individually configurable as Fire Water Flow or SupervisoryTwo 2A notification appliance circuitsSelectable NAC sync protocols6.5A power supplyAlarm verification selectable by zoneResettable aux power output rated at 0.3AAux power configurable to power off on Fire conditionFire trouble and supervisory relaysSingle person walk test functionOptional DACTAdvanced configuration options72 hour standby with 7Ah batteriesCompact enclosureUL864 listed

GBP 466.76
1

Kentec K1844-41 Sigma A-CP 4 Zone Control Panel 240V Grey

Kentec K1844-41 Sigma A-CP 4 Zone Control Panel 240V Grey

Kentec K1844-41 Sigma A-CP 4 Zone Control Panel 240V GreyThe Sigma A-CP is a range of conventional fire control panelswith an optional built-in communicator. With two four or eight initiatingcircuits all panels can be extensively configured via a simple front paneloperated programming method. The low standby power requirements and costeffective small batteries allow the panel to be mounted in a discrete enclosurewhich is available in red or grey. A simple programming method using just 3front panel buttons allows an extensive list of configuration options to be setand reviewed. Single board construction enables easy removal of all electronicparts by removing just two screws and ample provision of cable entry knockoutssimplify installation. 4 Amp notification appliance power and built-inselectable sync protocols provide ample power and control for a wide range ofstandard notification appliances. The built-in RS485 communications busprovides the facility to connect 4 wire annunciators or ancillary relay boardsto provide further indication and control options throughout a premises. Theoptional DACT allows dual line reporting to central stations and provides a500-event history buffer.Key Features4 Zone CircuitsInitiating circuits individually configurable as Fire Water Flow or SupervisoryTwo 2A notification appliance circuitsSelectable NAC sync protocols6.5A power supplyAlarm verification selectable by zoneResettable aux power output rated at 0.3AAux power configurable to power off on Fire conditionFire trouble and supervisory relaysSingle person walk test functionOptional DACTAdvanced configuration options72 hour standby with 7Ah batteriesCompact enclosureUL864 listed

GBP 431.34
1