302 results (0,15237 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Apollo Integrated Base Sounder - Slow Whoop with Isolator 45681-290APO

Apollo Xpander Diversity Loop Interface Unit - XPA-IN-14050-APO

Apollo Xpander Diversity Loop Interface Unit - XPA-IN-14050-APO

Please note The XPA-IN-14050-APO does not support CoreProtocol installations.Apollo Xpander Diversity Loop Interface Unit - XPA-IN-14050-APOThe XPander Diversity Loop Interface Unit can monitor up to 31 XPander devices and report each devices status to an intelligent fire control panel.Brand InformationXPander incorporates entirely new designs with respect to the wireless communication system. A Radio Interface is connected to the loop. It communicates with the control panel using the Apollo addressable two-wire power and communications system. The interface communicates with the detection and alarm signalling devices by means of radio waves. The detectors are multistate in that they report normal pre-alarm fire or fault states to the radio base which transmits the information to the interface.The detectors incorporate drift compensation and report any compensation limit occurring. The radio bases and signalling devices are addressable and use a pre-set analogue value to report via the XP95 or Discovery protocol. Apart from normal and fire the bases can send pre-set analogue values to indicate low battery detector contaminated detector tamper and low signal strength fault conditions.Key FeaturesConnects up to 31 XPander devices to an ApolloAddressable loopTranslates radio signals from XPander detectors to the fire control panelBuilt-in loop isolatorLoop-poweredDiversity aerial design for improved signal integrityThe entire XPander product line has a temporary four-month supply disruption starting from November 2021 with supply expecting to resume in February 2022.

GBP 337.68
1

Apollo XP95 Multisensor Detector 55000-885APO

Apollo XP95 Multisensor Detector 55000-885APO

Apollo XP95 Multisensor Detector 55000-885APOThe XP95 multisensor Detector contains an optical smoke sensor and a thermistor temperature sensor whose outputs are combined to give the final analogue value.The multisensor construction is similar to that of the optical detector but uses a different lid and optical mouldings to accommodate the thermistor temperature sensor. The sectional view shows the arrangement of the optical chamber and thermistor.The signals from the optical smoke sensing element and the temperature sensor are independent and represent the smoke level and the air temperature respectively in the vicinity of the detector.The detectors microcontroller processes the two signals.The temperature signal processing extracts only rate of rise information for combination with the optical signal. The detector will not respond to a slow temperature increase - even if the temperature reaches a high level. A large sudden change in temperature can however cause an alarm without the presence of smoke if sustained for 20 seconds.The processing algorithms in the multisensor incorporate drift compensation. The control panel must not have a drift compensation algorithm enabled. The sensitivity of the detector is considered the optimum for most general applications since it offers good response to both smouldering and flaming fires.Key FeaturesSensitive to a wide range of firesWell suited for environments such as hotel bedroomsUnaffected by wind or atmospheric pressureOther part codes include AD-2004

GBP 39.53
1

Apollo 45681-300APO Integrated Base Sounder - DIN-Tone with Isolator

Apollo 45681-300APO Integrated Base Sounder - DIN-Tone with Isolator

Apollo 45681-300APO Integrated Base Sounder - DIN-Tone with IsolatorThe Integrated Base Sounder comprises of a base sounder with integral mounting base and is for use with Discovery or XP95 ranges. It is designed for indoor use.Electrical DescriptionThe integrated base sounder is line powered and needs no external power supply. It operates at 1728V DC and is polarity-sensitive.Mechanical ConstructionThe integrated base sounder is moulded in polycarbonate and has stainless steel contacts that accept solid or stranded cables of up to 2.5mm.Device AddressingADDRESSING The integrated base sounder responds to its own individual address set with a DIL switch. It also responds both to a group address set by means of a 4-segment DIL switch and to a pulsed-mode synchronisation address which is embedded in the unit. GROUP ADDRESSING It may be desirable in alarm conditions to switch more than one integrated base sounder simultaneously. To enable this sounders may be controlled as a group and given a group address which is common to all sounders in the group. When a device recognises its group address it will process the forward command bits but it will not return any data to the control panel on that ad dress. If it is required to confirm the status of the outputs of devices under group address control it is necessary to interrogate all devices in the group at their individual addresses.CommunicationXP95 Discovery and CoreProtocol compatibleKey FeaturesTwo tonesTwo volume ranges 55-75dBA and 75-91dBAIndividual and group addressingUnique acoustic self-testBuilt-in isolator

GBP 37.24
1

Apollo XPander Remote Indicator Module - XPA-IN-14102-APO

Apollo XPander Single Input Output Channel Unit - XPA-IN-14011-APO

Apollo XPander Dual Input Output Channel Unit - XPA-IN-14012-APO

Apollo XP95 Heat Detector Standard Temperature 55000-400APO

Apollo XP95 Heat Detector Standard Temperature 55000-400APO

Apollo XP95 Heat Detector Standard Temperature 55000-400APOThe XP95 Heat Detector monitors temperature by using a single thermistor which provides a count output proportional to the external air temperature. The XP95 range features two heat detectors standard and high temperature. The standard heat detector is classified as an A2S device and will report an alarm at 55C. The high temperature detector classified as a CS device will report an alarm at 90C.Brand InformationThe XP95 range of analogue addressable fire detectors uses tried and trusted technology to give the best performance and has unique features that benefit the installer and the end user. It is suitable for medium-to-large applications with simple installation requirements. As it operates using digital communication XP95 has a high immunity from corruption and is therefore often preferred in a large system where life safety is critical. XP95 products are frequently used in commercial industrial financial government ITtelecoms and healthcare applications.OperationThe XP95 heat detectors have a low air flow resistance case made of self-extinguishing white polycarbonate. The devices monitor heat by using a single thermistor network which provides a voltage output proportional to the external air temperature.The standard heat detectors 55000-400 and 55000-420 respond to increasing air temperature in such a way that they are classified as an A2S device. Both devices will give 55 counts at 55C. A high temperature CS heat detector 55000-401 which can be installed in a typical ambient temperature of 55C is available. This device will give 55 counts at 90C.Key FeaturesIdeal in environments that are dirty or smoky under normal conditionsWell-suited to warehouses loading bays and car parksUnaffected by wind or atmospheric pressureOther part codes include AD-2002

GBP 32.66
1

Apollo Orbis Heater Detector Base - ORB-HB-00020-APO

Apollo XPander CS Heat Detector XPA-HT-11171-APO

Apollo Indoor Intrinsically Safe Manual Call Point 470 ohm - 55100-031APO

Apollo Orbis TimeSaver Sav-Wire Base ORB-SW-10005-APO

Apollo XP95 Intelligent Duct Smoke Detector - 53546-022APO

Apollo XPander A1R Heat Detector XPA-HT-11170-APO

Apollo XPander A1R Heat Detector XPA-HT-11170-APO

Apollo XPander A1R Heat Detector XPA-HT-11170-APOThere are two heat detectors in the XPander range designed to suit a wide variety of operating conditions. A Static Heat Detector CS which responds only when a fixed temperature has been reached and a Rate-of-Rise Detector A1R which has a fixed upper limit but in addition measures the rate of increase in temperature.OperationHeat detectors have an open-web casing which allows air to flow freely across a thermistor which measures the air temperature every 2 seconds. A microprocessor stores the temperatures and compares them with pre-set values to determine whether a fixed upper limitthe alarm levelhas been reached. In the case of rate-of-rise detectors the microprocessor uses algorithms to determine how fast the temperature is increasing. Static heat detectors respond only when a fixed temperature has been reached. Rate-of-rise detectors have a fixed upper limit but they also measure the rate of increase in temperature. A fire might thus be detected at an earlier stage than with a static detector so that a rate-of-rise detector is to be preferred to a static heat detector unless sharp increases in temperature are part of the normal environment in the area protected by the heat detector.Key FeaturesWireless Can be used in applications where smoke detectors are unsuitableIdeal for environments that are dirty or smoky under normal conditionsCS detectors are ideal for use in environments with rapid temperature fluctuations such as boiler rooms Bi-directional monitored radio platformFive-year battery life using standard AA alkaline batteries

GBP 69.42
1

Apollo AlarmSense CS Heat Detector High Temperature 55000-193APO

Apollo XP95 Intelligent Heater Base 45681-219APO

Apollo Marine Isolating Base 45681-286MAR

Apollo AlarmSense A1R Heat Detector Standard 55000-190APO

Apollo AlarmSense A1R Heat Detector Standard 55000-190APO

Apollo AlarmSense A1R Heat Detector Standard 55000-190APOThere are two heat detectors in the AlarmSense range designed to suit a wide variety of operating conditions. A static heat detector CS which responds only when a fixed temperature has been reached and a rate-of-rise detector A1R which has a fixed upper limit but in addition measures the rate of increase in temperature.AlarmSense is a range of conventional fire detection and alarm products designed to be connected to the same pair of supply wires making installation quicker and less expensive. AlarmSense has been developed to make the design and installation of a fire detection and alarm system easier and more economic for small to medium-sized buildings. The range also allows an existing system to be extended or modified if necessary. This flexibility makes AlarmSense an excellent choice for use in HMOs House in Multiple Occupation. As you would expect from Apollo AlarmSense incorporates features that help reduce false alarms and patented technology to ensure the integrity of a system. The range also includes products such as beacons to help meet the requirements of the Disability Discrimination Act DDA.Brand FeaturesFlexibleReliableCost-effectiveCompliant with BS 5839Easy to installEasy to extendProduct InformationThere are two heat detectors in the AlarmSense range designed to suit a wide variety of operating conditions. A static heat detector CS which responds only when a fixed temperature has been reached and a rate-of-rise detector A1R which has a fixed upper limit but in addition measures the rate of increase in temperature.Key Features Can be used for applications where smoke detectors are unsuitableIdeal environments that are dirty or smoky under normal conditionsCS detectors are ideal for use in environments with rapid temperature fluctuations such as boiler rooms360C visibility of LEDsReduction offalse alarmsQuick and simple installation

GBP 12.85
1

Apollo Marine DIN-Rail Zone Monitor 55000-773MAR

Apollo Marine DIN-Rail Dual Isolator 55000-770MAR

Apollo XP95 DIN-RAIL Zone Monitor with Isolator - 55000-812APO

Apollo Series 65 Conventional Duct Smoke Detector - 53546-021APO

Apollo Soteria Dimension Mounting Box FL5000-200APO