338 results (0,14794 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Ziton ZP2-AF1-S ZP2-A - 1 Loop Addressable Panel

Ziton ZP2-AF1-S ZP2-A - 1 Loop Addressable Panel

Ziton ZP2-AF1-S ZP2-A - 1 Loop Addressable PanelCertification EN54-2 EN54-4 EN54-2OverviewThe new ZP2-A series life safety control systems bring the speed and functionality of high-end intelligent processing to small to mid-sized addressable applications. Based on ZP2 series learned experience and with complete backwards compatibility the new ZP2-A features an attractive contemporary design that fits with any decor. With improved robustness manufactured in metal special plastics and easy electronics removal it allows painting in any colour. The main controls are easily located using an improved and robust jog dial.The PanelThe fire panels supplied in local language with user interface with 1 loop that supports up to 254 devices 127 addresses in 512 zones have standard 2 supervised sounderfire-routing outputs which can be used as freely programmable outputs as well. In addition 2 conventional relay outputs and 2 supervised outputs working in pair and dedicated to common fire and fault conditions as well as 2 user configurable inputs for monitoring and control are available.OptionsThe panel supports one network board to create a maximum of 64 nodes 256 loops network of fire panels and fire panel repeaters including conventional fire panels and fire repeater panels up to a maximum of 64 conventional zones. Last but not least in case seperate zone indications are required a 20 or a 40 zone firefault LED indicator board can be mounted in the panel or repeater with ample space for custom text. Compatible with existing loop devices and network compatible with existing panels repeaters existing and new and conventional panelsApprovals compliance CE CPD EN54-2 EN54-4 EN54-21 WEEE RoHS compliantDetails 1 High Power Loop with 800 mA per loop 512 zones and 300 output groups Up to 24 LED zone indicators for Fire and Fault with space for a 4 digit number Auto configuration setup wizards and default regional setup modes Ethernet port with TCPIP for remote diagnostics maintenance and programming EN54 compliant graphical LCD with icons and up to 256 zones Improved Jog Dial with 4 soft buttons for simple and intuitive user control Aesthetic pleasing design with robust painted steel door Easy removable door and chassis for quick and clean installation All pluggable connectors

GBP 564.11
1

Ziton ZP2-AF1 ZP2-A - 1 Loop Addressable Panel

Ziton ZP2-AF1 ZP2-A - 1 Loop Addressable Panel

Ziton ZP2-AF1 ZP2-A - 1 Loop Addressable PanelCertification EN54-2 EN54-4 EN54-2The new ZP2-A series life safety control systems bring the speed and functionality of high-end intelligent processing to small to mid-sized addressable applications. Based on ZP2 series learned experience and with complete backwards compatibility the new ZP2-A features an attractive contemporary design that fits with any decor. With improved robustness manufactured in metal special plastics and easy electronics removal it allows painting in any colour. The main controls are easily located using an improved and robust jog dial.The PanelThe fire panels supplied in local language with user interface with 1 loop that supports up to 254 devices 127 addresses in 512 zones have standard 2 supervised sounderfire-routing outputs which can be used as freely programmable outputs as well. In addition 2 conventional relay outputs and 2 supervised outputs working in pair and dedicated to common fire and fault conditions as well as 2 user configurable inputs for monitoring and control are available.OptionsThe panels supports one network board to create a maximum of 64 nodes 256 loops network of fire panels fire panel repeaters including conventional fire panels and fire panel repeaters up to a maximum of 64 conventional zones. Last but not least in case seperate zone indications are required a 20 or 40 zone firefault LED indicator board can be mounted in the panel or repeater with ample space for text. Compatible with existing loop devices and network compatible with existing panels repeaters existing and new and conventional panels.Approvals compliance CE CPD EN54-2 EN54-4 EN54-21 WEEE RoHS compliantDetails 1 High Power Loop with 800 mA per loop Up to 512 zones and 300 output groups Up to 40 LED Zone indicators for Fire and Fault with ample text space Auto configuration setup wizards and default regional setup modes Ethernet port with TCPIP for remote diagnostics maintenance and programming EN54 compliant graphical LCD with icons and up to 256 zones Improved Jog Dial with 4 soft buttons for simple and intuitive user control Aesthetic pleasing design with robust painted steel door Easy removable door and chassis for quick and clean installation All pluggable connectors Auxiliary 24 VDC supply output with reset support 3 USB ports with memory stick support and RS232 for printer support Communication via UltraSync cloud using EN 54-21 UC240 UltraSync communicator Integration in management software ATS8600 allowing integration with security systems and CMS 3 operator level menu structure 20 usernames and passwords Email notification for events directly from the panel 4 user accounts History log memory for 9999 events Backwards compatible supporting site retrofitupgrades expansions replacement Compatible with the Ziton loop powered soundersbeacons and base sounders and Ziton series detectors

GBP 564.11
1

Ziton ZP2-AF2-S-99 ZP2-A 2 Loop Addressable Fire Panel Small Cabinet

Ziton ZP2-AF2-S-99 ZP2-A 2 Loop Addressable Fire Panel Small Cabinet

Ziton ZP2-AF2-S-99 ZP2-A 2 Loop Addressable Fire Panel Small CabinetThe Ziton ZP2-AF2-S-99 addressable fire alarm panel has 2 loops that support up to 254 devices each 127 addresses in 512 zones have standard 2 supervised sounderfire-routing outputs which can be used as freely programmable outputs as well. In addition 2 conventional relay outputs and 2 supervised outputs working in pair and dedicated to common fire and fault conditions as well as 2 user configurable inputs for monitoring and control are available.OptionsThe panel supports an extra 2 loop board that brings the panel to up to 512 zones with 4 additional programmable outputs. Add a network board to create a maximum of 64 nodes 256 loops network of fire panels and fire panel repeaters including conventional fire panels and fire repeater panels up to a maximum of 64 conventional zones. Last but not least in case seperate zone indications are required a 20 or a 40 zone firefault LED indicator board can be mounted in the panel or repeater with ample space for custom text.Compatible with existing loop devices and network compatible with existing panels repeaters existing and new and conventional panels.ZP2-A Panel OverviewThe new ZP2-A series life safety control systems bring the speed and functionality of high-end intelligent processing to small to mid-sized addressable applications. Based on ZP2 series learned experience and with complete backwards compatibility the new ZP2-A features an attractive contemporary design that fits with any decor. With improved robustness manufactured in metal special plastics and easy electronics removal it allows painting in any colour. The main controls are easily located using an improved and robust jog dial.With high power loop addressable detection a full line of easily configured option cards and modules as well as USB and Ethernet connectivity these quick-to configure systems offer versatility that benefits building owners and life safety system installers alike.Key Features2 High Power Loop expandable to 4 with 800 mA per loop512 zones and 300 output groupsUp to 24 LED Zone indicators for Fire and Fault with space for a 4 digit numberAuto configuration setup wizards and default regional setup modesEthernet port with TCPIP for remote diagnostics maintenance and programmingEN54 compliant graphical LCD with icons and up to 256 zonesImproved Jog Dial with 4 soft buttons for simple and intuitive user controlAesthetic pleasing design with robust painted steel doorEasy removable door and chassis for quick and clean installationAll pluggable connectorsAuxiliary 24 VDC supply output with reset support3 USB ports with memory stick support and RS232 for printer supportCommunication via UltraSync cloud using EN 54-21 UC240 UltraSync communicatorIntegration in management software ATS8600 allowing integration with security systems and CMS3 operator level menu structure 20 usernames and passwordsEmail notification for events directly from the panel 4 user accountsHistory log memory for 9999 eventsBackwards compatible supporting site retrofitupgrades expansions replacementCompatible with the Ziton loop powered soundersbeacons and base sounders and Ziton series detectors

GBP 801.02
1

Ziton ZP3AB-NLM3 Class-A Network Loop Module

Ziton ZP3AB-NLM3 Class-A Network Loop Module

Ziton ZP3AB-NLM3 Class-A Network Loop ModuleThe ZP3AB-NLM network loop module enables individual ZP3 control panels to be connected in a peer to peer secure loop network. If there is an open or short circuit present on the network wiring the NLMs determine where the fault lies isolate the faulty section of wiring and maintain full loop integrity.Total cable length throughout the network can be up to a maximum of two kilometres and may be extended by setting designated NLM modules as booster units contact Ziton technical support department for full details. Communication between loop modules operates by RS485 protocol over screened twisted pair wiring.Unique address on the network loopZP3AB-NLM3 modules connect to ZP3 control panels via a ZP3AB-NET1 card and are designed to fit onto an auxiliary chassis inside each control panel or auxiliary equipment cabinet. Each ZP3 control panel is connected to the loop network through an ZP3AB-NLM3 module. All modules incorporate switch settings enabling them to be assigned a unique loop address. An output fault signal is provided by a volt free changeover relay with contacts rated at 1A at 230VDC30VAC.Diagnostic and system indicationIn each network loop one module must be set to address 1 and designated as the master. This device manages the healing sequence and monitors loop integrity. All other modules are connected to the network loop in slave mode.In slave mode modules can operate in multiple modesBoost - serving as an interconnection between panels at distances over 1000 metresHealing establishing the condition of the loop and isolating sections if necessaryRecovered normal condition after a section isolationDiagnostic system interrogation to establish the location of a break in the loop wiringIn addition to indications of data being transmitted and received from each port LED indicators are also provided for System OK Loop Fault Loop Open and Data Error.Key FeaturesProvides a secure loop networkEnhanced LED diagnosticsBoost mode for long cable runsPropagation time periods for third party equipment operationCommunications screen isolation between input and output channels

GBP 277.06
1

Ziton ZP2-AF2-PRT-99 ZP2-A 2 Loop Addressable Fire Panel with Printer Large Cabinet

Ziton ZP2-AF2-PRT-99 ZP2-A 2 Loop Addressable Fire Panel with Printer Large Cabinet

Ziton ZP2-AF2-PRT-99 ZP2-A 2 Loop Addressable Fire Panel with Printer Large CabinetThe Ziton ZP2-AF2-PRT-99 addressable fire alarm panel with printer has 2 loops that support up to 254 devices each 127 addresses in 512 zones have standard 4 supervised sounderfire-routing outputs which can be used as freely programmable outputs as well. In addition 2 conventional relay outputs and 2 supervised outputs working in pair and dedicated to common fire and fault conditions as well as 2 user configurable inputs for monitoring and control are available.OptionsThe panel supports an extra 2 loop board that brings the panel to up to 512 zones with 4 additional programmable outputs. Add a network board to create a maximum of 64 nodes 256 loops network of fire panels fire panel repeaters including conventional fire panels and fire panel repeaters up to a maximum of 64 conventional zones. Last but not least in case seperate zone indications are required a 20 or 40 zone firefault LED indicator board can be mounted in the panel or repeater with ample space for text.Compatible with existing loop devices and network compatible with existing panels repeaters existing and new and conventional panels.ZP2-A Panel OverviewThe new ZP2-A series life safety control systems bring the speed and functionality of high-end intelligent processing to small to mid-sized addressable applications. Based on ZP2 series learned experience and with complete backwards compatibility the new ZP2-A features an attractive contemporary design that fits with any decor. With improved robustness manufactured in metal special plastics and easy electronics removal it allows painting in any colour. The main controls are easily located using an improved and robust jog dial.With high power loop addressable detection a full line of easily configured option cards and modules as well as USB and Ethernet connectivity these quick-to configure systems offer versatility that benefits building owners and life safety system installers alike.Key FeaturesBuild-in thermal printer with paper replacement from the front2 High Power Loop expandable to 4 with 800 mA per loopUp to 512 zones and 300 output groupsUp to 40 LED Zone indicators for Fire and Fault with ample text spaceAuto configuration setup wizards and default regional setup modesEthernet port with TCPIP for remote diagnostics maintenance and programmingEN54 compliant graphical LCD with icons and up to 256 zonesImproved Jog Dial with 4 soft buttons for simple and intuitive user controlAesthetic pleasing design with robust painted steel doorEasy removable door and chassis for quick and clean installationAll pluggable connectorsAuxiliary 24 VDC supply output with reset support3 USB ports with memory stick support and RS232 for printer supportCommunication via UltraSync cloud using EN 54-21 UC240 UltraSync communicatorIntegration in management software ATS8600 allowing integration with security systems and CMS3 operator level menu structure 20 usernames and passwordsEmail notification for events directly from the panel 4 user accountsHistory log memory for 9999 eventsBackwards compatible supporting site retrofitupgrades expansions replacementCompatible with the Ziton loop powered soundersbeacons and base sounders and Ziton series detectors

GBP 1242.37
1

Ziton ZP2-AFR-99 ZP2-A Addressable Fire Repeater Panel

Ziton ZP2-AFR-99 ZP2-A Addressable Fire Repeater Panel

Ziton ZP2-AFR-99 ZP2-A Addressable Fire Repeater PanelThe Ziton ZP2-AFR-99 addressable fire panel repeater comes with a 2010-2-NB network board already fitted. Except for having no addressable loops and corresponding programmable outputs the setup is similar as a normal fire panel. It and has its own power supply 2 conventional relay outputs and 2 supervised outputs working in pair and dedicated to common fire and fault conditions as well as 2 user configurable inputs for monitoring and control are available.OptionsThe repeaters use a node on the network similar like a normal panel with a maximum of 64 nodes 256 loops network of fire panels and fire panel repeaters including conventional fire panels and fire panel repeaters up to a maximum of 64 conventional zones. Last but not least in case separate zone indications are required a 20 or 40 zone firefault LED indicator board can be mounted in the panel or repeater with ample space for text.Network compatible with existing panels repeaters existing and new and conventional panels.ZP2-A OverviewThe new ZP2-A series life safety control systems bring the speed and functionality of high-end intelligent processing to small to mid-sized addressable applications. Based on ZP2 series learned experience and with complete backwards compatibility the new ZP2-A features an attractive contemporary design that fits with any decor. With improved robustness manufactured in metal special plastics and easy electronics removal it allows painting in any colour. The main controls are easily located using an improved and robust jog dial.With high power loop addressable detection a full line of easily configured option cards and modules as well as USB and Ethernet connectivity these quick-to configure systems offer versatility that benefits building owners and life safety system installers alike.Key Features Local or global repeater with or without global control functionality Up to 40 LED zone indicators for Fire and Fault with ample text space Auto configuration setup wizards and default regional setup modes Ethernet port with TCPIP for remote diagnostics maintenance and programming EN54 compliant graphical LCD with icons and up to 256 zones Improved Jog Dial with 4 soft buttons for simple and intuitive user control Pleasing design with robust painted steel door Easy removable door and chassis for quick and clean installation All pluggable connectors 3 USB ports with memory stick support and RS232 for printer support 3 operator level menu structure 20 usernames and passwords Email notification for events directly from the panel 4 user accounts History log memory for 9999 events Backwards compatible supporting site retrofitupgrades expansions replacement Comes standard fitted with network board

GBP 717.90
1

Ziton FD310 End-to-End Beam Detector 5 to 120m

Ziton FD310 End-to-End Beam Detector 5 to 120m

Ziton FD310 End-to-End Beam Detector 5 to 120mOptical beam smoke detector consists of separate transmitter and receiver heads and a low level controller.The FD310 End to End infrared Optical Beam Smoke Detector OBSD has been designed using the latest optical technology incorporating modern industrial electronic and software techniques. This detector offers cost effective protection of large open area spaces with high ceilings. It is also very suited to applications where access to ceiling mounted smoke detectors presents practical difficulties.The system comprises a modern looking Transmitter head which emits a narrow beam of infra-red light to an associated Receiver head with a compact Low Level Controller. Once smoke crosses through and thus obscures the IR beam path the signal strength at the Receiver drops below a pre-set level which in turn results in an alarm condition. Both the detector heads Transmitter and Receiver have integrated alignment thumbwheels for ease of alignment. Using these thumbwheels provides a smooth and repeatable alignment process. The detector heads have up to 10 degrees of adjustment in both planes. For further adjustment a bespoke Adjustment Bracket is available which offers up to 180 degrees movement in both planes as well as a full 360-degree rotation.The FD310 has been designed so that it can be installed by one operator with its laser assisted alignment method combined with easy to use alignment LEDs offering a visual feedback. Integrated laser alignment aid can be activated at the Controller or at the Receiver head.The low level Controller incorporates a LCD display which offers a full icon-based easy-to-use interface unit. This Controller enables ease of commissioning testing and maintenance of the beam detection system. During commissioning the detector sensitivity and fire thresholds can be selected along with the user variable time to fire and time to fault settings.Range 5 to 120m integral laser alignment controller can support 2 pairs of transmitter and receivers additional pairs are available FD310H.Key FeaturesSeparate Transmitter and Receiver HeadsRange 5 to 120 metres configurable per set of DetectorsIntegral Laser Alignment in Receiver2-wire Interface between Controller and ReceiverSingle and Twin Detector optionsSeparate Fire and Fault Relays per DetectorLow Level Controller with LCD displayProgrammable Sensitivity and Fire ThresholdAutomatic Gain Control AGC for drift compensationFirst Fix concept for Transmitter Receiver and ControllerMultiple cable gland knockouts for ease of wiringOptional Transmitter powering from ControllerSupply voltage 12-36VDCCurrent Controller 14mA per transmitter head 8mAFire and Fault relays per detector head - rated 2A 30VDCDetector head dimensions per transmitter and receiver unit mm 74w x 74h x 161dController dimensions mm 203w x 124h x 73d

GBP 947.02
1

Ziton Surface Box for A Series Modules IP66 2 Single or 1 Double

Ziton ZPR868-CM Protocol 868Mhz Radio Cluster Communicator Mains Powered

Ziton ZPR868-CM Protocol 868Mhz Radio Cluster Communicator Mains Powered

Ziton ZPR868-CM Protocol 868Mhz Radio Cluster Communicator Mains PoweredThe ZPR868-CM is a mains powered wireless cluster communicator for interfacing Ziton wireless 868 MHz fire alarm devices into a ZP fire alarm system. It enables these wireless devices to be controlled directly from the ZP7 compatible CIE and provides a seamless interface between wireless devices and the CIE.System designA cluster communicator comprises of a radio transceiver capable of communicating with up to 31 wireless devices. Every cluster communicator communicates directly to a ZPR868-H hub or should direct communication not be possible via another cluster communicator with up to 4 hops to the hub. This allows for full meshed networked wireless systems with multiple redundant wireless communication parts as well as longer wireless communication ranges when that is required on large sites.Seamless addition of wireless devicesEvery wireless device controlled through a cluster communicator has its own unique address with which the main fire alarm control panel communicates with it providing the same system capabilities as directly wired devices. A full range of wireless detection and alarm devices is available including multi-sensors capable of dual sensing heat and smoke smoke only or heat only configurations manual call points notification devices sounders beacons as well as inputoutput units.Full flexibilityWireless devices are featured in many fire detection and alarm systems specified where the installation of hard wiring would be difficult or impossible to complete decorative finishes to the interior of the protected building preclude wiring runs or where the time scales to complete installation are minimal. Cluster communicators allow the system designer full flexibility in selecting the locations of wireless devices anywhere in the system or even allow all the filed devices in system to be wireless up to 508 devices per CIE or 127 devices per loop.Key FeaturesMains supply with battery backup2-Way communication with up to 31 wireless devicesDiversity transceivers allow maximum operational rangeVariable power outputETSI 300-220 approvedEN54-4 18 25 complaint and CPR certified

GBP 364.58
1

Ziton ZPR868-C 868Mhz Radio Cluster Communicator RCC 24Vdc

Ziton ZPR868-C 868Mhz Radio Cluster Communicator RCC 24Vdc

Ziton ZPR868-C 868Mhz Radio Cluster Communicator RCC 24VdcThe ZPR868-C is a 24VDC powered wireless cluster communicator for interfacing Ziton wireless 868 MHz fire alarm devices into a ZP fire alarm system. It enables these wireless devices to be controlled directly from the ZP7 compatible CIE and provides a seamless interface between wireless devices and the CIE.System designA cluster communicator comprises of a radio transceiver capable of communicating with up to 31 wireless devices. Every cluster communicator communicates directly to a ZPR868-H hub or should direct communication not be possible via another cluster communicator with up to 4 hops to the hub. This allows for full meshed networked wireless systems with multiple redundant wireless communication parts as well as longer wireless communication ranges when that is required on large sites.Seamless addition of wireless devicesEvery wireless device controlled through a cluster communicator has its own unique address with which the main fire alarm control panel communicates with it providing the same system capabilities as directly wired devices. A full range of wireless detection and alarm devices is available including multi-sensors capable of dual sensing heat and smoke smoke only or heat only configurations manual call points notification devices sounders beacons as well as inputoutput units.Full flexibilityWireless devices are featured in many fire detection and alarm systems specified where the installation of hard wiring would be difficult or impossible to complete decorative finishes to the interior of the protected building preclude wiring runs or where the time scales to complete installation are minimal. Cluster communicators allow the system designer full flexibility in selecting the locations of wireless devices anywhere in the system or even allow all the filed devices in system to be wireless up to 508 devices per CIE or 127 devices per loop.Key Features24VDC supply2-Way communication with up to 31 wireless devicesDiversity transceivers allow maximum operational rangeVariable power outputETSI 300-220 approvedEN54-4 18 25 complaint and CPR certified

GBP 364.58
1

Ziton FD310H - Additional Detector Pair 5 - 120m for FD310

Ziton FD310H - Additional Detector Pair 5 - 120m for FD310

ZitonFD310H - Additional Detector Pair 5 - 120m for FD310The FD310 End to End infrared Optical Beam Smoke Detector OBSD has been designed using the latest optical technology incorporating modern industrial electronic and software techniques. This detector offers cost effective protection of large open area spaces with high ceilings. It is also very suited to applications where access to ceiling mounted smoke detectors presents practical difficulties.OperationThe system comprises a modern looking Transmitter head which emits a narrow beam of infra-red light to an associated Receiver head with a compact Low Level Controller. Once smoke crosses through and thus obscures the IR beam path the signal strength at the Receiver drops below a preset level which in turn results in an alarm condition. Both the detector heads Transmitter and Receiver have integrated alignment thumbwheels for ease of alignment. Using these thumbwheels provides a smooth and repeatable alignment process. The detector heads have up to 10 degrees of adjustment in both planes. For further adjustment a bespoke Adjustment Bracket is available which offers up to 180 degrees movement in both planes as well as a full 360-degree rotation.The FD310 has been designed so that it can be installed by one operator with its laser assisted alignment method combined with easy to use alignment LEDs offering a visual feedback. Integrated laser alignment aid can be activated at the Controller or at the Receiver head.The low level Controller incorporates a LCD display which offers a full icon-based easy-to-use interface unit. This Controller enables ease of commissioning testing and maintenance of the beam detection system. During commissioning the detector sensitivity and fire thresholds can be selected along with the user variable time to fire and time to fault settings.Key FeaturesSeparate Transmitter and Receiver HeadsRange 5 to 120 metres configurable per set of DetectorsIntegral Laser Alignment in Receiver2-wire Interface between Controller and ReceiverSingle and Twin Detector optionsSeparate Fire and Fault Relays per DetectorLow Level Controller with LCD displayProgrammable Sensitivity and Fire ThresholdAutomatic Gain Control AGC for drift compensationFirst Fix concept for Transmitter Receiver and ControllerMultiple cable gland knockouts for ease of wiringOptional Transmitter powering from Controller

GBP 789.20
1

Ziton AD105P-0100 Alarmline 105 Degree Alarm Temperature Digital Sensor Cable PVC and Poly

Ziton AD88P-0500 Alarmline 88 Degree Alarm Temperature Digital Sensor Cable PVC and Poly

Ziton AD88-0100 Alarmline 88 Degree Alarm Temperature Digital Sensor Cable PVC

Ziton AD105SS-0500 Alarmline 105 Degree Alarm Temperature Digital Sensor Cable PVC and Stainless Steel

Ziton AD105-0500 Alarmline 105 Degree Alarm Temperature Digital Sensor Cable PVC

Ziton AD185N-0500 Alarmline 185 Degree Alarm Temperature Digital Sensor Cable

Ziton AD88SS-0500 Alarmline 88 Degree Alarm Temperature Digital Sensor Cable PVC and Stainless Steel

Ziton AD88SS-0100 Alarmline 88 Degree Alarm Temperature Digital Sensor Cable PVC and Stainless Steel

Ziton AD185N-0100 Alarmline 185 Degree Alarm Temperature Digital Sensor Cable

Ziton AD88-0500 Alarmline 88 Degree Alarm Temperature Digital Sensor Cable PVC