193 results (0,16814 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Cooper MCIM Micro Single Channel Input Unit recognised as a input unit

Cooper CFVCHP VoCall Type A Flush Mounted Outstation

Cooper CFVCSHP VoCall Type A Surface Mounted Outstation

Cooper TA16-BEZ Type A Outstation Bezel Red Flush Mount

Cooper Menvier TA16-RS Type A Outstation - Red - Surface Mount

Cooper Menvier TA16-SS Type A Outstation - Stainless Steel - Surface Mount

Cooper TA16-SS-BEZ Type A Outstation Bezel - Stainless Steel - Flush Mount

Cooper Menvier DAX8 Digital Analogue Exchange 8 Line

Cooper Menvier DAX8 Digital Analogue Exchange 8 Line

Cooper Menvier DAX8 Digital Analogue Exchange 8 LineDAX8 is a loop powered digital to analogue convertorused in conjunction with VoCALL 16 to ensure simplicityof future legacy system upgrade or expansion.This loop powered convertor allows the connectionof existing analogue outstations to a digital system. Amaximum of 8 analogue outstations of any combinationcan be connected to the DAX8 with a maximum of twoDAX8 units per panel. The loop wired connection to theDAX8 along with short circuit insulators ensures thenetwork is robust and fault tolerant.Compatible analogue outstations include the type Atype B Jack point and emergency assist alarm EAA.Utilising a minimum of one MX panel and up to 31additional lower cost NX network panels the DAX8enables system takeovers of up to 512 analogueoutstations utilising existing Eaton loop and radial cableconfigurations.The simplicity of operation ease of cabling andcompetitive pricing makes the system suitable for awide range of applications. The DAX8 can be wiredin combination with our range of soft addressabledigital outstations ensuring the maximum fl exibility intakeovers upgrades and expansion of EVC systems.The DAX8 also ensures compatibility with our low-costjack point for regions where this system is allowed bybuilding code allowing up-to 512 individually addressedjack points per system or 512 lines of jack points withpotentially over 10240 points available.Key FeaturesUp to 64 DAX8 units within a networkUp to 8 analogue outstations per DAX84 core loop connection to host panel8 x 2 core radial spurs for legacy analogue outstationsUpgrade existing systems to a digital isolated networkRequires at-least 1 MX panel per systemAny other combination of panels MXNX possibleAny combination of analogue outstations possible.Easy to install and commissionSoft addressed panel digital outstation and DAX8Embedded Webserver application for configurationLoop isolators built into the DAX8Built in end of line monitoring of legacy outstationsDill switch identification for legacy outstationsUses existing CFVCX8 footprintEmergency assist toilet alarms are powered from the DAX8Fully compliant with BS5839-9Network capacity of 512 outstations

GBP 609.11
1

Cooper MCOM Micro Single Channel Output Unit recognised as a output unit

Cooper MCOM-S Micro Single Channel Output Unit recognised as a sounder

Cooper Menvier EF-T107 2 x 70v Transformer Standard

Cooper Menvier MX16 16 Line Master Panel

Cooper Menvier MX16 16 Line Master Panel

Cooper Menvier MX16 16 Line Master PanelThe MX16 Digital VoCALL 16 Line Master Panel is a high specification digital loop driven intelligent emergency Voice Communication System offering sophisticated functionality along with a simple and intuitive end user interface.The network version enables a system installation of up to 32 main panels MX and network panels NX in any combination a minimum of 1 MX is required. With a maximum of 16 outstations per panel a total system size of 512 outstations is possible all connected and communicating via isolated fault tolerant loops.Digital audio communication achieves high audio quality and intelligibility whilst the use of isolated loops reduces labour and material costs removing the potential for wiring errors associated with traditional spur systems.The VoCALL 16 is a high specification digital loop driven intelligent Emergency Voice Communication System offering sophisticated functionality along with a simple and intuitive end user interface.This network version enables a system installation of up to 32 main panels MX and network panels NX in any combination a minimum of 1 MX is required. With a maximum of 16 outstations per panel a total system size of 512 outstations is possible all connected and communicating via isolated fault tolerant loops.The system also uses digital audio communication to achieve high audio quality and intelligibility when it matters the most. The use of isolated loops also reduces labour and material cost along with potential for wiring errors associated with traditional spur systems.VoCALL16 is designed to ensure the simplicity of future expansion. Continuous fault monitoring and reporting ensures high availability. Extensive time stamped logs ensure ease of debugging and recording for compliance.Key FeaturesNetwork capacity of 512 outstationsUp to 32 panels mainnetwork in a loopUp to 16 digital outstations per panel4 core loop configurations two for power two for dataSimple to design networkAt least one main panel is requiredAny combination of panels MXNX possibleAny combination of outstations possibleCentrally controlled by a main panelEasy to install and operateAutomatic soft addressing of panels and outstationsPC based application for configurationComplex call routing is possibleExtensive time stamped logs on SD cardLarge graphical user interfacePIN protected user accessFully compliant with BS5839-9

GBP 1446.23
1

Cooper Bi-Wire Conventional Repeater Panel EFBWCV-REPEATER

Cooper CF3000PRG Intelligent Addressable Touch Screen Repeater Panel DF6000PRG FX6000PR

Cooper CF3000PRG Intelligent Addressable Touch Screen Repeater Panel DF6000PRG FX6000PR

Cooper CF3000PRG Intelligent Addressable Touch Screen Repeater Panel DF6000PRG FX6000PRThe control panel has the ability to support complex cause and effect programming and a wide range of user controllable functions make the system ideal for a diverse range of projects from industrial applications through to large multi-site commercial developments.The ULCF3000 uses soft addressing to minimise installation time and remove the potential for error associated with manual addressing.Each of the system components have been specifically designed to operate as part of a ULCF3000 UL Listed system providing assurance that the panel the detectors the interfaces and the ancillaries are all fully compatible with each other and that the full range of system functionality is supported by each device.Key FeaturesTouchscreen Display2 or 4 Class A Style 7 SLC loopsEvent History Buffer 9999 events with DateTime stamp4 Notification appliance circuits NACs outputs3 programmable general purpose relaysDedicated alarm and trouble relaysShort circuit isolators incorporated into each loopUp to 200 addresses per loopFully monitored network cable up to 126 panelsOptional integral printerAlarm VerificationPAS Positive Alarm SequencPre-Signal per Point NFPA 70 72 compliantRemote Alarm NAC silenced Alarm Reset Trouble Supervisory and drill via addressable moduleBenefitsSupports a comprehensive range of soft addressing modules and devices for greater flexibility in designMenu driven graphical user interface for ease of operationReduced commissioning time through soft addressing and auto learn functionsProgramming and trouble-shooting time minimised by using a range of features such as auto config walk test system details analogue values etc

GBP 395.10
1

Cooper Menvier NX16 16 Line Network Panel

Cooper Menvier NX16 16 Line Network Panel

Cooper Menvier NX16 16 Line Network PanelThe NX16 is a 16 Line Network Panel designed for use with the VoCALL Network.If youre looking for an emergency voice communication system for a large project such as a high rise building or if future expansion is a key concern VoCALL 16 gives you that added flexibility. By connecting one or more network panels NX to a main panel MX you can increase reach of the system to suit your requirements.The VoCALL 16 is a high specification digital loop driven intelligent Emergency Voice Communication System offering sophisticated functionality along with a simple and intuitive end user interface.This network version enables a system installation of up to 32 main panels MX and network panels NX in any combination a minimum of 1 MX is required. With a maximum of 16 outstations per panel a total system size of 512 outstations is possible all connected and communicating via isolated fault tolerant loops.The system also uses digital audio communication to achieve high audio quality and intelligibility when it matters the most. The use of isolated loops also reduces labour and material cost along with potential for wiring errors associated with traditional spur systems.VoCALL16 is designed to ensure the simplicity of future expansion. Continuous fault monitoring and reporting ensures high availability. Extensive time stamped logs ensure ease of debugging and recording for compliance.Key FeaturesNetwork capacity of 512 outstationsUp to 32 panels mainnetwork in a loopUp to 16 digital outstations per panel4 core loop configurations two for power two for dataSimple to design networkAt least one main panel is requiredAny combination of panels MXNX possibleAny combination of outstations possibleCentrally controlled by a main panelEasy to install and operateAutomatic soft addressing of panels and outstationsPC based application for configurationComplex call routing is possibleExtensive time stamped logs on SD cardLarge graphical user interfacePIN protected user accessFully compliant with BS5839-9

GBP 1223.74
1

Cooper CIT420R Addressable 4-20mA Interface

Cooper CIOP4 4 Way Mimic Relay Board with 4 Inputs amp 4 Outputs

Cooper CIOP4 4 Way Mimic Relay Board with 4 Inputs amp 4 Outputs

Cooper CIOP4 4 Way Mimic Relay Board with 4 Inputs 4 OutputsThese addressable mimic relay boards CIOP4 and CIOP8 are 4 and 8 way soft addressing output modules incorporating integral short circuit isolators.Both the CIOP4 and the CIOP8 mimic relay boards are fully compatible with the current range of Cooper intelligent addressable control panels. The units are suitable for switching low voltage 24V dc at 1A maximum via a set of non-latching relay contacts.The flexibility of these modules is further enhanced by the fact that each output can be programmed for a range of triggers such as disablement fault fire test panel test zone pre-alarm fire routing equipment fire protecting equipment and reset with up to 16 different trigger sources per output.The trigger source can be global by panel by loop by zone or by address. The logic is available in both OR AND functions.These units have an additional 4 inputs which can initiate a reset silence evacuate and test function.They can be programmed using the CF3000 programmable site installer software and downloaded using the RS232 port.Key FeaturesLoop poweredUnits can be soft or hard addressedIntegral short circuit isolatorSingle address4 input 4 output version4 input 8 output versionPCB version incorporates 4 inputs- Reset- Silence- Evacuate- Test16 settings per outputTrigger types fire fault disablement test prealarm FRE FPE resetTrigger source global by panel by loop by zone by addressLogic functions OR ANDBenefitsQuick and simple to installPluggable terminals for ease of wiringProgrammable via site installer softwareCost effective installation solution

GBP 372.41
1

Cooper CIOP8 8 Way Mimic Relay Board with 4 Inputs amp 8 Outputs

Cooper CIOP8 8 Way Mimic Relay Board with 4 Inputs amp 8 Outputs

Cooper CIOP8 8 Way Mimic Relay Board with 4 Inputs 8 OutputsThese addressable mimic relay boards CIOP4 and CIOP8 are 4 and 8 way soft addressing output modules incorporating integral short circuit isolators.Both the CIOP4 and the CIOP8 mimic relay boards are fully compatible with the current range of Cooper intelligent addressable control panels. The units are suitable for switching low voltage 24V dc at 1A maximum via a set of non-latching relay contacts.The flexibility of these modules is further enhanced by the fact that each output can be programmed for a range of triggers such as disablement fault fire test panel test zone pre-alarm fire routing equipment fire protecting equipment and reset with up to 16 different trigger sources per output.The trigger source can be global by panel by loop by zone or by address. The logic is available in both OR AND functions.These units have an additional 4 inputs which can initiate a reset silence evacuate and test function.They can be programmed using the CF3000 programmable site installer software and downloaded using the RS232 port.Key FeaturesLoop poweredUnits can be soft or hard addressedIntegral short circuit isolatorSingle address4 input 4 output version4 input 8 output versionPCB version incorporates 4 inputs- Reset- Silence- Evacuate- Test16 settings per outputTrigger types fire fault disablement test prealarm FRE FPE resetTrigger source global by panel by loop by zone by addressLogic functions OR ANDBenefitsQuick and simple to installPluggable terminals for ease of wiringProgrammable via site installer softwareCost effective installation solution

GBP 380.40
1